Panasonic KX-TG1032SK Service Manual page 31

Telephone equipment expandable digital cordless answering system
Table of Contents

Advertisement

9.1.4.3.
Check Table for RF part
No.
Item
1
Link Confirmation Normal
HS, BU Mode: [Normal mode]
2
Control signal confirmation
HS, BU Mode: [Burst TX mode]
3
X'tal Frequency confirmation
4
TX Power confirmation (*5)
HS, BU mode
Checked unit: [Burst TX mode] (*1)
Regular unit: [Test RX mode] (*1)
5
RX Sensitivity confirmation (*5)
HS, BU mode
Checked unit: [Test RX mode] (*1)
Regular unit: [Burst TX mode] (*1)
6
Range Confirmation Normal
HS, BU Mode: [Normal mode]
Note:
(*1) Refer to Commands (P.47) for Base unit, and refer to Commands (P.52) for Handset.
(*2) Refer to RF-BBIC Interface Signal Wave Form (P.33)
(*3) Refer to Adjustment Standard (Base Unit) (P.48)
(*4) Refer to Adjustment Standard (Handset) (P.53)
(*5)
Caution for measuring RSSI:
It must be measured RSSI of reception unit when the timing of transmission corresponds to the timing of reception as below.
EX.) RSSI waveform
BU (Base Unit) Check
1. Register Regular HS to BU (to be
checked).
2. Press [Talk] key of the Regular HS to
establish link.
1. Check BBIC interface. (*2)
1. Check X'tal Frequency. (*3)
(10.368 MHz ± 100 Hz)
1. Place the Regular HS about 15cm away
from the BU.
2. Confirm that RSSI of the Regular HS is
approximately 0.85 V by Oscilloscope. (*3)
1. Place the Regular HS about 15cm away
from the BU.
2. Confirm that RSSI of the BU is approxi-
mately 0.85 V by Oscilloscope. (*3)
1. Register Regular HS to BU (to be
checked).
2. Press [Talk] key of the Regular HS to
establish link.
3. Compare the range of the BU (being
checked) with that of the Regular BU.
31
KX-TG1032SK/KX-TGA101S
HS (HandSet) Check
1. Register HS (to be checked) to Regular
BU.
2. Press [Talk] key of the HS to establish link.
1. Check BBIC interface. (*2)
1. Check X'tal Frequency. (*4)
(10.368 MHz ±100Hz)
1. Place the HS about 15cm away from the
Regular BU.
2. Confirm that RSSI of the Regular BU is
approximately 0.85 V by Oscilloscope. (*4)
1. Place the HS about 15cm away from the
Regular BU.
2. Confirm that RSSI of the HS is approxi-
mately 0.85 V by Oscilloscope. (*4)
1. Register HS (to be checked) to Regular
BU.
2. Press [Talk] key of the HS to establish link.
3. Compare the range of the HS (being
checked) with that of the Regular HS.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Kx-tga101s

Table of Contents