Bayer mode
Sleep between
snaps
Automatic gain
correction
Flicker-free
exposure
Average grey value
Color saturation
Button: "White
balance once"
because the flipping will change the starting pixels the Bayer
mode the mode has to be adjusted if flipping is done. In streaming
mode this setting has no effect
only used in webcam mode, not in streaming mode
enables the automatic exposure control
if 0 no flicker-free exposure is used. Gain is fixed to a medium
value and exposure is controlled by changing the exposure time
For values > 0 exposure time is limited to multiples of the value.
Exposure values in between are realized by changing the gain.
For 50Hz lighting flicker-free exposure is realized with a value of
820. For 60Hz the value should be set to 683
The average gray value of the whole image, the exposure control
tries to reach
color saturation of the result image in percent. 0 is black and
white, 100 neutral. The maximum lies at 200
if pressed the software calculates RGB parameters that set the
current scene to neutral white. This will take several seconds