Download Print this page

Sealey CD400 Instructions page 2

Convector heater 400w/230v

Advertisement

 DO NOT use the heater where there are flammable liquids, solids or gases such as petrol, solvents, aerosols etc, or where heat sensitive
materials may be stored.
 DO NOT place the heater immediately below any electrical outlet.
 DO NOT cover heater when in use, and do not obstruct the air inlet and outlet grille.
 Allow the unit to cool before storage. When not in use, disconnect from the mains power supply and store in a safe, cool, dry, childproof
area.
NOTE:This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities
or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and
understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children
without supervision
2.
INTRODUCTION
Modern, slimline design with rotary controlled room thermostat to maintain ambient temperature at pre-set level. Wall mountable with brackets
included or floor standing with wide feet for added stability. Ideal for home, light industrial and office environments. Supplied with 13Amp ASTA/
BS approved non-rewirable plug.
3.
SPECIFICATION
Model No: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . CD400
Power:. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 400W
Supply: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .230V
Size (W x D x H inc feet): . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 345 x 70 x 320mm (100mm Depth inc.Wall Brackets)
Weight: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.9kg
4.
ASSEMBLY
4.1.
Free Standing: attach the feet by securing them to the base using the self tapping screws provided (fig.1).
4.2.
Wall Mounted: do not attach the feet.
4.2.1. Choose a location suiting the provisions of fig.2.
4.2.2. Having ensured that the area chosen is free from hidden cables and pipes, mark the centres of the upper fixing holes as in fig.3. Use a
spirit level to ensure accuracy.
© Jack Sealey Limited