How To Install - LG Therma V AHUW056A3 Engineering Product Data Book

Air-to-water heat pump/split type r410a/50hz, total hvac solution provider
Hide thumbs Also See for Therma V AHUW056A3:
Table of Contents

Advertisement

THERMA V
Split Type
10. Accessories
10.5.2 Installation
WARNING
1. Do not Install, remove, or re-install the unit by yourself (customer).
There is risk of fire, electric shock, explosion, or injury.
2. For installation, always contact the dealer or an Authorized Service Center.
There is risk of injury.
3. Be cautious when unpacking and installing the product.
Sharp edges could cause injury. Especially careful on the product edges.
CAUTION
1. Install the drain hose to ensure that water is drained away properly.
A bad connection may cause water leakage and unpleasant odor.
2. Do not install the Product without gloves.
There are sharp and moving parts that could cause personal injury.
 How to install
1. Uncover the front panel.
3. Attach the Insulator (c), (d) to the rear side of the
base pan.
5. Remove the knock-out from the bottom of the front
panel.
34
2. Assemble the Drain pan(b).
- Four pipes are fastened by ties.
- Cut the unnecessary part of ties.
Ti Ti Tiee
e
4. Attach the Insulator (a) to the bottom of the base
pan.
6. Insert the Insulator (b) into the front panel.
Hydro Box Unit