Power supply

The electrical power unit consists of a reversable single phase condensor motor with integrated electronic stop switch, brake
and transmission .
The lift can be controlled via:
1 . Radio remote control
2 . IR remote control
3 . Media control system
(e .g . Kindermann, AMX, etc .) No . 5699 000 022
4 . Key switch
5 . Up/down switch
The connection with the power supply should be via the power socket of the lift and an external socket with on/off switch .
All wiring goes through the appropriate opening in the upper frame . The connection cable for the projector and the cables for
the safety switches have been pre-mounted on the right hand pairs of the concertina elements . Use the cable guides on the
left hand pairs of the concertina elements for installating the signal and control cables .
Fix the supplied flexible spiral and the cable clips, then the signal and control cables in the same way as the pre-mounted cables .
Thus the cords cannot be squeezed or otherwise be damaged by the concertina elements .
Circuit diagramme – installaion of switches
Mains
Projector switch
Switch for rop control
Projector
Ceiling lift
Circiut diagramme – programming unit
Mains
PE N L
Projector switch
Switch for rop control
Projector
Ceiling lift
No . 5699 000 020
No . 5699 000 021
No . 5944 000 001
No . 5944 000 002
blue
blue
black
black
brown
brown
yellow/green
yellow/green
Power socket
ceiling lift
blue
blue
black
black
brown
brown
yellow/green
yellow/green
Power socket
ceiling lift
Mains
Junction box
Switches
Switch box
Mains
Programming unit
7466 000 100 or
7466 000 101