Input & Output Control - Dalsa BOA2-XAX-INS Installation Manual

Smart vision system with inspect express software
Table of Contents

Advertisement

Input Control via iNspect Express
The iNspect Express application provides two options for controlling the inputs on
BOA2. These are selected in the "Control" panel of the GUI as shown below. Click on
the GUI cells to change the control parameters.
Each input supports a noise filter called "debounce". A signal must remain active for the
duration of the filter to be considered valid. The debounce settings range from 1us to
64ms. GPI0 is a special input that is used either as a Trigger or general purpose input.
When used for triggering, the polarity of this input is programmable.
BOA2 inputs are available to the script tool for synchronizing with external events.
Output Control via iNspect Express
The iNspect application provides two options for controlling the outputs on BOA2.
These are selected in the "Control" panel of the GUI as shown below. Click on the GUI
cells to set the Driver, polarity and associated pulse parameters.
Note: The Strobe driver uses the offset/duration settings defined in the sensor panel. The
active polarity only affects the external STROBE output.
BOA2-XA Installation
31
Version 4.3; 2017-11-20