Ethernet and I/O Setup

1.
Connect the M12-8 male end of the Ethernet cordset (A-BVS2-E8S-X) to the M12-
8 female connector labeled "LAN" on the camera.
2.
Connect the RJ45 end of the Ethernet cordset to the RJ45 on the client PC, PLC
or factory LAN (PC is only required for setup)
3.
Connect camera PWR, GND and I/O from the control panel to the breakout screw
terminals on the PL-101.
4.
Connect the M12-12 male end of the IO-PWR cordset (A-BVS2-IO12S-X) to the
M12-12 female connector on the camera labeled "IO/PWR"
5.
If required, connect the M12-5 lamp cable (A-BVS-L5S) between the camera
"LAMP" connector and the light
6.
Connect the Trigger and I/O to the PL-101 as required for the application
BOA2 System
BOA2-XA Installation
A-BVS2-E8S-X
A-BVS-PL-101
Power
Inputs
Outputs
Setup client PC
11