Samsung Duct Type Series Installation Manual page 30

Hide thumbs Also See for Duct Type Series:
Table of Contents

Advertisement

Setting an indoor unit address and installation option
Option
SEG7
Explanation
PAGE
Indication Details Indication
Indication
and Details
1
Option
SEG13
Explanation
PAGE
Indication Details Indication
Indication
and Details
2
Option
SEG19
Explanation
PAGE
Indication Details Indication Details Indication
Indication
and Details
3
(*1) When COOL or DRY mode is off. The indoor fan operate in setting minutes.
(*2) Minimizing fan operation when thermostat is off
- Fan operates for 20 seconds at an interval of 5 minutes in HEAT mode.
- Fan stops or operates Ultra low in Cooling when thermostat is off.
(*3) 1: Fan is turned on continually when the hot water heater is turned on,
3: Fan is turned off when the hot water heater is turned on with cooling only indoor unit
Cooling only indoor unit: To use this option, install the Mode Select switch(MCM-C200) on the outdoor unit and fix it
as COOL mode.
(*4) When the following 2 or 3 is used as external heater On/Off signal, the signal for monitoring external contact control
will not be output.
2: Fan is turned on continually when the external heater is turned on,
3: Fan is turned off when the external heater is turned on with cooling only indoor unit
Cooling only indoor unit: To use this option, install the Mode Select switch(MCM-C200) on the outdoor unit and fix it
as COOL mode.
30
SEG8
Use of drain pump
Use of hot water heater
Details
Indication
0
Disuse
0
1
Use
1
When an
indoor unit
stops, drain
2
3
pump will
operate for
3min
SEG14
Setting the output of external control /
Use of external control
External heater signal / Cooling operation
signal / Free Cooling control signal
Details
Indication
0
Disuse
0
1
ON/OFF
1
control
2
3
OFF
2
control
4
5
Window
3
ON/OFF
control
6
SEG20
Individual control of a
Heating setting compensation
remote controller
0 or 1
channel 1
0
2
channel 2
1
3
channel 3
4
channel 4
2
SEG9
Details
Disuse
Use (*3)
Use (*3)
SEG15
Details
External control (Thermo On)
External control (Operation On)
External heater signal (*4)
External heater signal (*4)
Cooling operation signal (*5)
Free Cooling control (Cooling
Thermo On) (*6)
Free Cooling control (Cooling/
Dry Thermo On) (*6)
SEG21
Adjusted EEV step of
stopped unit during
oil return /defrost
Details
Indication Details
Default
2 °C
5 °C
SEG10
SEG11
EEV Step when
heating stops
Indication Details
0
Default
Adjusted
1
EEV Step
setting
SEG16
SEG17
Buzzer control
Indication Details Indication Details
Use
0
buzzer
Disuse
1
buzzer
SEG22
SEG23
mode
0
Default
Adjusted
1
EEV
positon
SEG12
SEG18
Hours of filter usage
1000
2
Hour
2000
6
Hour
SEG24

Advertisement

Table of Contents
loading

This manual is also suitable for:

Big duct am fnhdch series

Table of Contents