Contents
1. Introduction .......................................................................................................................... 2
2. In general ............................................................................................................................. 2
3. Ranges of application .......................................................................................................... 3
4. Operation ............................................................................................................................. 3
5 Installation ............................................................................................................................ 4
6. Servicing .............................................................................................................................. 5
7. Guarantee regulations ......................................................................................................... 5
8. Security tips .......................................................................................................................... 5
9. Recognising and repairing of mistakes ................................................................................ 6
10. Notes on Product Liability .................................................................................................... 6
11. Notes on Disposal ............................................................................................................... 7
12. EU Declaration of Conformity .............................................................................................. 7
13. Technical Data ................................................................................................................... 16
safety InstruCtIon and WarnInGs
Please read the user manual
before using the device
Warning sign
1. IntroduCtIon
We would like to congratulate you on the purchase of our pump. We appreciate your trust.
That's why funtional security and operational safety stands by us on first place.
to prevent damage to persons or property, you should read this user manual
carefully. please observe all safety precautions and instructions for proper use
of the pump. failure to follow the instructions and safety precautions can result
in injury or property damage.
please keep this manual with the instructions and safety instructions carefully
in order to at any time you can restore them. please always download the latest
version of the user manual of www.profi-pumpe.de under „downloads". This
shall always prevail.
2. In General
The pumps in the catagorie Centrifugal Pumps are developed according to the newest stand of
technology, manufactured with much care and go under strict intensive controls.
The pumps have been optimized by us especially for the special requirements for circulating
and filtering large volumes of water. Make sure after unpacking the pump that the data given
on the type label agree with the included operating instructions. In the case of doubt the pump
is not to be used. Transport damages are immediately to be reported to the package distributor
and to us in witten form.
Pull power plug
Warning of electrical voltage
3. ranGes of applICatIon
These pumps are made for pumping clear water (free of mud and sand, see technical data)
The pumps are made for the following ranges of application:
l In private and in public swimming pool
l Circulating large volumes of water
l Other Clear water pumping
IMportant!
The pumps are designed for pumping clean water and chemically non-aggressive liquids. Any
guarantee is void in case of improper use. They are not suitable for pumping flammable liquids
or for use in places where there is danger of an explosion. The pumps are designed for home
use in the house and garden.
These pumps are intended for private use in the home and garden. These pumps are not desi-
gned for continuous use (without interruptions). In continuous operation mode, the lifetime will
be shortened accordingly. Never run more than 5 minutes against a closed valve pump. Save
the pump against dry running (install dry run protection).
never start and stop the pump more than 20 times per hour. When the pump clocks, any
claim under warranty is void.
not suitable for use with solar photovoltaic panels.
4. operatIon
The installation must be performed by a qualified professional.
Please, check each time before using, the electrical connections and the cables are not
damaged. Check before the installation whether the electrical connections are earthed
according to the statutory regulations and are installed. The pump is to be secured
through a RCD circuit breaker with release current of 30 mA. is technically correct, so
this warranty is void. It must be ensured that the pump is sufficiently cooled during pro-
longed operation.
It is not recommended to perform even cable extensions or any other technical modifications.
The lines to the pump must be installed always steadily rising. A transfer of mechanical loads or
vibrations from the pump or to the pump must be eliminated through appropriate actions (use of
rubber buffers, braided hoses, line fixation, etc.).
Do not reduce the suction line. All pipe/hose connections to and from the pump must be sealed.
We recommend that you implement the suction line „as one piece" without any interruption in
order to prevent and avoid leaks. Check pump and water lines for leaks by pressure testing min.
24 hrs.
Is dirt expected in the pump, an effective pre-filter should be installed before the pump inlet. Fill
pump and suction
pipe/hose with water. Please connect electrically pump with power supply. Start the pump. If ne-
cessary, the pump and the suction line must be refilled until a normal continuous operation has
been established.
note: Note: Please note that a tapering of the pump connections can lead to a defect in the
pump. The specified connection sizes should be strictly adhered to here. These are guaranteed
when using the supplied step hose adapter.
Please observe item 5.2 under „step hose adapter asseMbly".
If the flow on the pressure side of the pump is severely restricted (e.g. by clogged sand filters),
water may come out of the housing.