olympia electronics Slim Light Series Quick Start Manual page 2

Maintained/non-maintained luminaires

Advertisement

Figure 1
Diffusor
Reflector
Plastic base
For fuse ratings
see text
Figure 4
1. To instal the device you have to dismantle carefully the device with a flat screwdriver as shown in
figure 1.
2. Pass the mains cables thru the hole (point 1 in figure 2). The luminaire must be connected to a
permanent electrical installation to ensure the immobilization of the cable.
3. Mount the base plastic on the wall by using the included mounting accessories in points 2 and 3 in
figure 2.
4. Connect the battery`s cable with the appropriate terminal (figure 3).
5. Connect the mains cables to the terminal block as shown in figure 4.
6. Refit with care the removed plastic parts and power on the luminaire.
NOTE!!
After finishing the installation you must power the luminaire at least for 24 hours for battery
charging to perform the named autonomy.
NOTE: LED= Light Emitting Diode
LABELING EXPLANATION:
X: Self contained
1: Maintained (*)
A: Including test device
90: 1.5 hour duration
180: 3 hour duration
Battery replacement.
It can be done only by a competent person and after the mains interruption.
1. Dismantle the device (step 1 of the installation instructions).
2. Disconnect the connector and remove the old battery.
3. Connect the new battery with the same type (step 4 of the installation instructions) and place it in
the position of the old one.
4. Follow the step 6 of the installation procedure and power the device.
Page 2 from 2
Installation instructions
1
3
Figure 2
(*) Maintained operation: The luminaire lights its
illumination source, when it is powered by the
mains power supply or not.
Non-Maintained operation: The luminaire lights its
illumination source, only in power supply's
failure.
2
4
Non-maintained
Maintained
operation
operation
923378005_23_001
Figure 3

Advertisement