Download Print this page
Lithonia Lighting TWR2 Instructions
Lithonia Lighting TWR2 Instructions

Lithonia Lighting TWR2 Instructions

Wall pack

Advertisement

Quick Links

SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION
INSTALLATION
INSTRUCTIONS
Wall Pack
WARNING
WARNING
WARNING
WARNING
WARNING
RISK OF FIRE - Lamps are hot. Keep
combustible material away from hot
parts.
WARNING
WARNING
WARNING
WARNING
WARNING
RISK
OF
FIRE
-
manufacturer's warnings, recommenda-
tions and restrictions on lamp operation
and maintenance.
IMPORTANT SAFETY
INSTRUCTIONS
• Do not install a damaged fixture.
• This fixture must be wired in accordance
with the National Electrical Code and
applicable local codes and ordinances.
• Proper grounding is required to ensure
personal safety. Be certain green lead
from the fixture is connected to supply
ground.
• Use code compliant connectors for all
electrical connections.
• ALL work should be done by a qualified
electrician.
• WARNING: NEVER connect or disconnect
any component while power supply is
engaged.
Upon receipt of fixture and accesso-
DELIVERY:
ries (packed separately), thoroughly inspect for
any freight damage. All damage should be
reported to the delivery carrier. Do not install
damaged fixtures. Compare the catalog de-
scription listed on the packing slip with the fix-
ture label on the inside of the housing to be sure
you have received the correct merchandise.
WARNING: FAILURE TO FOLLOW THESE INSTRUCTIONS AND WARNINGS MAY RESULT IN DEATH,
INJURY, OR SIGNIFICANT PROPERTY DAMAGE
and instructions carefully before installing or maintaining this fixture. These instructions do not attempt to
cover all installation and maintenance situations. If you do not understand these instructions or additional
information is required, contact Lithonia Lighting or your local Lithonia Lighting distributor.
WARNING: RISK OF ELECTRIC SHOCK -
all electrical power is disconnected from the supply branch circuit conductors before installing or main-
taining this fixture. This product must be installed and maintained in accordance with the applicable instal-
lation codes by a person familiar with the construction and operation of the product and the hazards
involved.
WARNING: RISK OF PERSONAL INJURY -
prevent cuts or abrasions when removing from carton, handling, installing and maintaining this product.
Lithonia Lighting assumes no responsibility for claims arising out of improper or careless installation or
handling of this product.
If this fixture fails to operate properly, check to
make sure:
The correct lamp is properly installed.
The fixture is wired correctly.
The lamp is not faulty.
Observe
lamp
The fixture is grounded correctly.
The line voltage at the fixture is correct.
Read carefully before installing light fixtures. If you do not understand these instructions, please
contact your local Lithonia distributor before installing.
MOUNTING - Wall pack is designed to allow for a variety of mounting configurations. It can be
mounted directly to a recessed junction box or mounted directly to the wall for wiring via
surface conduit from either side or the top. DO NOT AIM UP . NOT INTENDED FOR MOUNTING
INVERTED OR ON CEILING.
JUNCTION BOX MOUNTING
1. Remove the lamp, reflector, and component cover and keep them in a safe place.
2. Look at the back of the rear housing to locate the pre-cast locators that match most
standard junction-box mounting locations. Using a hammer and punch or drill, prepare the
housing by knocking out only the appropriate mounting holes, along with the center wiring
access hole.
3. Install the provided self-adhesive gasket to the back of the fixture to cover the junction box.
4. Align the back housing correctly and mount securely.
5. Use code compliant connectors to connect fixture leads to supply leads, being careful to
follow the wiring directions below.
6. Replace the component cover and reflector and install the lamp, being careful to follow the
re-lamping directions below.
7. Replace front cover. Make sure that the lens gasket is properly seated around the perimeter
of the cover to insure a weathertight seal.
8. Make sure all wiring access holes are sealed with weatherproof silicone sealant.
NOTE: Fixture must be installed per all applicable national and local codes.
SAVE THESE INSTRUCTIONS
IMPORT T T T T ANT SAFETY INSTRUCTIONS
IMPOR
IMPOR
ANT SAFETY INSTRUCTIONS
ANT SAFETY INSTRUCTIONS
ANT SAFETY INSTRUCTIONS
IMPOR
IMPOR
ANT SAFETY INSTRUCTIONS
To avoid electric shock, serious injury, or death, be certain that
TROUBLESHOOTING
Prior to Installation
INSTALLATION
- For your protection, read and follow these warnings
This product may have sharp edges. Wear gloves to
CAUTION
Observe lamp manufacturer's recommendations
and restrictions on lamp operations, including but
not limited to ballast type, burning position, and
cycling. Use ANSI rated lamps only.
Maintenance: For optimum performance,
periodically clean reflector and lens with a soft,
damp cloth.
Important: DO NOT use abrasive materials, glass
cleaner or other solvents on lens or paint. Use only
mild, soapy water.
2003 © Acuity Lighting Group, Inc., Rev B 08/09/07
RJ5210140
INST SHT TWR2

Advertisement

loading

Summary of Contents for Lithonia Lighting TWR2

  • Page 1 This product may have sharp edges. Wear gloves to prevent cuts or abrasions when removing from carton, handling, installing and maintaining this product. Lithonia Lighting assumes no responsibility for claims arising out of improper or careless installation or handling of this product.
  • Page 2 3. Secure front cover to housing. Be sure that the gasket is firmly seated in the proper channel prior to closing fixture to maintain weather-tight seal. 4. Re-connect the power. 2003 © Acuity Lighting Group, Inc., Rev B 08/09/07 SAVE THESE INSTRUCTIONS RJ5210140 INST SHT TWR2...