Advertisement

Quick Links

1312AQ937
280PRO
1050603
Original-Gebrauchsanleitung
V1/0217

Advertisement

Table of Contents
loading

Summary of Contents for Bartscher 280PRO

  • Page 1 1312AQ937 280PRO 1050603 Original-Gebrauchsanleitung V1/0217...
  • Page 2: Table Of Contents

    Important tips ..................... 44 5.2.2 Device switch on/off ................... 45 6. Cleaning and maintenance ..................46 7. Possible Malfunctions .................... 47 8. Waste disposal ......................48 Bartscher GmbH Franz-Kleine-Str. 28 D-33154 Salzkotten phone: +49 (0) 5258 971-0 Germany fax: +49 (0) 5258 971-120...
  • Page 3: Safety

    Read these instructions before using and keep them available at all times! This instruction manual contains information about the installation, operation and maintenance of the device and should be consulted as an important source of information and reference guide. Awareness of the safety instructions and instructions for use in this manual will ensure the safe and correct use of the device.
  • Page 4: Safety Instructions

    HOT SURFACE! This symbol is a warning that the device surface is hot when in use. Ignoring this warning may result in burns! CAUTION! This symbol highlights dangerous situations which could lead to light injuries, or damage, malfunction, and/or destruction of the device. NOTE! This symbol highlights recommendations and information aimed for effective and trouble-free device operation.
  • Page 5 Do not use the device in enclosed areas. • Install the device in a well-ventilated room, if possible under the • exhaust hood, in order to ensure extraction of all gases created during combustion. For proper combustion, the air inflow cannot be lower than 2 m /h per kW of rated power of the device (see: rating plate attached to the device).
  • Page 6 WARNING Risk of burns! To avoid the hazard results please follow the safety instructions below. During the ignition process, never lean over the cooking area. • High flames from this area my lead to severe burns. Never touch the hot surface of the gas burner during its •...
  • Page 7: Proper Use

    1.3 Proper use CAUTION! The device has been designed and built for commercial use and should be operated only by qualified personnel in kitchen facilities. The operational safety of the device is assured only in case of proper use, according to the operation manual.
  • Page 8: General Information

    2. General information 2.1 Liability and Warrantees All the information and instructions in this manual take into account standard safety regulations, current levels of technical engineering as well as the expertise and experience we have developed over the years. The instruction manual was translated with all due care and attention. However, we do not accept liability for any translation errors.
  • Page 9: Transport, Packaging And Storage

    3. Transport, packaging and storage 3.1 Delivery check Please check the delivery upon completeness and transport damage immediately after receipt. In case of visible damage do not accept or accept the delivery with reservation only. Note the extent of damage on the carrier’s bill of delivery. Trigger off the complaint. Hidden damages should be reclaimed immediately after notice, as claims for damages can only be asserted within the effective period for complaints.
  • Page 10: Technical Data

    4. Technical data 4.1 Technical specification Name Gas stock-pot stove 280PRO 1050603 Art. no.: Nickel-chrome steel 18/10 Material: Cast iron support Type of gas: Propane, Natural gas nozzles H and L are included Gas burner: nozzle burner Type of ignition: manual ignition...
  • Page 11 Table 2: Features of Burners and nozzles Category II2ELL3B/P Type A Design Burner Nominal heat output (kW) 12.5 Gas consumption - Natural gas LL (m 1.54 - Natural gas E 1.32 - Liquid gas (kg/h) 0.98 Natural gas LL Pilot flame Min.
  • Page 12 CAUTION! The device operates properly only when the pressure in the gas distribution grid is between the values provided in the table below for various gas types. Application of gas categories in different countries Country of destination Gas supply pressure Category FR-BE 20/25;...
  • Page 13: Overview Of Parts

    4.2 Overview of parts Figures Fig. 1 Fig. 2 1 Housing 2 Feet 3 Burner knob 4 Removable fat drip drawer 5 Tin holder 6 Cast iron ribbed support 7 Nozzle burner - 36 -...
  • Page 14 Fig. 3 A - Gas manifold B - Pressure control connector C - Sealing screw Fig. 4 A - Burner body B - Thermocouple C - Pilot flame D - Venturi tube E - Air regulating bush F - Nozzle Fig.
  • Page 15 Fig. 6 A - Upper part of the burner B - Nozzle C - Double taper ring D - Thermocouple E - Gas tube screw F - Sealing screw Fig. 7 A - OFF position B - Pilot flame position C - Max.
  • Page 16: Installation And Operation

    5. Installation and operation 5.1 Instructions for the Installer CAUTION! Any installation, connection and maintenance work must be performed only by the qualified, possibly authorized personnel, who meets the following requirements: a) approved by our company: b) certificate of the local gas supplier. Apart from these requirements, the following regulations must be observed: 1) DVGW TRGI (Technical regulations regarding gas installations);...
  • Page 17: Preset

    5.1.2 Preset Never place the device in toxic or explosive environment. • Never place the device near flammable materials, such as petrol, fat, clothes, • liquid gas, paper etc. Never place the device in wet room / environment, such as e.g. rain or near •...
  • Page 18: Gas Connection

    5.1.3 Gas connection Before the installation of the device and its connection to the gas supply, carefully • inspect the elements of gas installation which should comply with the provisions of the Building Code. Check the pipes diameters in order to ensure sufficient supply to all the gas-heated •...
  • Page 19: Adjustment To Another Gas Type / Required Settings

    Delivery pressure control If the measurements show bigger deviations, carefully check the diameter and quality • of embedded nozzles, as well as a delivery pressure. Delivery pressure should comply with the following values: 20 mbar for gases of second group (natural gas) G20/G25 50 mbar for gases of third group (butane / propane) G30/G31 Delivery pressure may be measured on the working device with the use of a liquid •...
  • Page 20 b) Control valve (Fig. 5) Replace a screw (B) according to the Table 2 of technical data. If the control valve is set properly, the flame surrounds the thermocouple and burns correctly. There is no need to adjust the primary air for the control valve. c) Burner nozzle (Fig.
  • Page 21: User Instructions

    5.2 User instructions CAUTION! Carefully read this operation manual as it contains instructions for safety and operation of the device. Store the manual to use it at any moment. The defective installation, operation errors and maintenance and cleaning mistakes as well as any modifications may cause the incorrect operation, damages and injuries.
  • Page 22: Device Switch On/Off

    5.2.2 Device switch on/off WARNING! Risk of burns! During the flame ignition, never lean over the device. High flames from this area my lead to severe burns. Pilot flame ignition (Fig. 7) Press the burner knob and turn left to MAX position (C), hold the knob pressed •...
  • Page 23: Cleaning And Maintenance

    6. Cleaning and maintenance WARNING! Before cleaning, disconnect the device from the gas supply (close the gas shut-off valve). Wait for the unit to cool. Never clean the device with flammable or explosive liquids. Vapors may cause fire or explosion. Never use water jet to wash the device.
  • Page 24: Possible Malfunctions

    Maintenance by the gas installer Observing the following instructions will ensure an optimum operation of the device: any maintenance and repair work must be performed by an authorized gas specialist; have the device checked at least once a year; we recommend concluding a relevant service agreement;...
  • Page 25: Waste Disposal

    In order to prevent possible unauthorized use and related dangers, before disposal of the device make sure that it cannot be started and then deliver it to the appropriate local collection point. Bartscher GmbH Franz-Kleine-Str. 28 D-33154 Salzkotten phone: +49 (0) 5258 971-0...

Table of Contents