fig.3
5. Maintenance
warninG! disconnect saw from air supply before changing the blade or file, servicing or performing
maintenance. replace or repair damaged parts. Use genuine parts only. Unauthorised parts may be
dangerous and will invalidate the warranty.
5.1
unless the air supply system includes an oiler, lubricate the air saw daily with a few drops of air tool oil,
dripped into the air inlet before use (sealey part no's. Ato500s (500ml) or Ato1000s (1 litre).
5.2
loss of power or erratic action may be due to the following:
a) excessive drain on the air line. moisture or restriction in the air line. incorrect size or type of hose
connectors. to remedy, check the air supply and follow instructions in section 3.
b) Grit or gum deposits in the saw may also reduce performance. if your model has an air strainer
(located in the area of the air inlet), remove the strainer and clean it. flush the saw out with gum
solvent oil or an equal mixture of sAe no 10 oil and kerosene. Allow to dry before use. if you continue to
experience problems, contact your local sealey service agent.
5.3
for a full service, contact your local sealey service agent.
5.4
When not in use, disconnect from air supply, clean saw and store in a safe, dry, childproof location.
reciprocating Air saw, model no. sA342 when operated in accordance with these instructions and tested in
accordance with Bs en 28662-1:1993, iso 8662-1:1988 and
vibration emission declared in accordance with Bs en 12096:1996.
Measured vibration emission value: 50m/s²
these values are suitable for comparison with emission levels of other tools that have been subject to the same
test.
this tool may cause hand-arm vibration syndrome if its use is inadequately managed.
recommended Measures to reduce risk of hand-arm vibration syndrome:
this tool should not be used by an individual regularly for more than 2.45 minutes in any 8 hour period.
this duration of use should be reduced if the individual is exposed to hand-arm vibration from other sources.
NOTE: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice.
iMPortant: no liability is accepted for incorrect use of this product.
warranty: Guarantee is 12 months from purchase date, proof of which will be required for any claim.
inforMation: for a copy of our latest catalogue and promotions call us on 01284 757525 and leave your full name and address, including postcode.
risk of Hand arm Vibration injury
sole uK Distributor, sealey Group,
Kempson Way, suffolk Business Park,
Bury st. edmunds, suffolk,
iP32 7Ar
Original Language Version
Bs en iso 8662-12:1997
uncertainty: 20m/s²