Besantek BST-DL08 Manual

Single-use usb pdf temperature data logger

Advertisement

Quick Links

Test Equipment Depot - 800.517.8431 - 99 Washington Street Melrose, MA 02176 - TestEquipmentDepot.com
BST-DL08
Single-Use USB PDF Temperature
Data logger
Manual
V1.0
BESANTEK Corporation, CANADA

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the BST-DL08 and is the answer not in the manual?

Questions and answers

Summary of Contents for Besantek BST-DL08

  • Page 1 Test Equipment Depot - 800.517.8431 - 99 Washington Street Melrose, MA 02176 - TestEquipmentDepot.com BST-DL08 Single-Use USB PDF Temperature Data logger Manual V1.0 BESANTEK Corporation, CANADA...
  • Page 2: Table Of Contents

    1.3Produ ct Feature ........................! 1.4Performance Parameters ......................1 Cha p ter II: Instruction Manua ................2 2.1 Instrument appearance specification ..................2 2.2 Instrument instructions ......................3 2.3PDF document description ..................... 5 Cha p ter Ill: Precautions ..................8 BESANTEK Corporation, CANADA...
  • Page 3: Cha P Ter I: Product Introduction

    Instrument will connected with the computer to automatically generate PDF documents to view the analysis data more convenient and quick 1.4Performance Parameters Parameter Parameter index Parameter Parameter index 1/2AA3.6V Lithium Measuring Voltage -30~70 °C battery temperature range BESANTEK Corporation, CANADA...
  • Page 4: Cha P Ter Ii: Instruction Manua

    4 - lower limit lamp : the temperature exceeds the lower limit state, the light is on every 10 seconds once, indicating the measured temperature exceeds the lower limit. Test Equipment Depot - 800.517.8431 - 99 Washington Street Melrose, MA 02176 - TestEquipmentDepot.com BESANTEK Corporation, CANADA...
  • Page 5 - Open the Datalogger software - Click [Get] to get the instrument configuration - Pop-up the ok prompt window, click [OK] - set the instrument upper and lower limits alarming and interval logging - click [Sync Setting] synchronization settings. BESANTEK Corporation, CANADA...
  • Page 6 2.lnstrument boot, enter calibration mode: After synchronizing time, the instrument is pulled out from the computer, press the OK button to power on, Two LED lights at the same time, the instrument enters the calibration mode, normal display real-time temperature, can BESANTEK Corporation, CANADA...
  • Page 7: Pdf Document Description

    1.PDF generation: After the instrument is connected to a computer, the PDF document will be generated. At this time, the temperature light will flash and the representative is Test Equipment Depot - 800.517.8431 - 99 Washington Street Melrose, MA 02176 - TestEquipmentDepot.com BESANTEK Corporation, CANADA...
  • Page 8 ---t l:43 20Hrtvt6 2011111116 20171UN6 Date/Time Tflt!IP. Figure 2-6 PDF Document Page 1 1) Instrument serial number and software version 2) Over limit alarm prompt: blank= no alarm, red= alarm. 3) Set the recording interval, unit: second BESANTEK Corporation, CANADA...
  • Page 9 201711 Utli 09:20:52 2ll.5 2D1711V1612:32:52 215.7 2017111"6 to:ss::52 211..7 ... 1011'11 tlM Ol:21::12 -.. 2011;111'111�-, »1711 V1112::D::G 211.1 .,...,..,._,, ...,. .,..,.••-•--• Figure 2-6 PDF Document Page 2 temperature over limit display blue, if not display black. Data display: BESANTEK Corporation, CANADA...
  • Page 10: Chapter Ill Precautions

    4. It can not be used for the second time if the instrument power off when recording the data, so please do not turn off or connect the machine to the computer during the recording process. (VER 1.0) Test Equipment Depot - 800.517.8431 - 99 Washington Street Melrose, MA 02176 - TestEquipmentDepot.com BESANTEK Corporation, CANADA...