Installation And Connection - AMC DT16 Installation Instructions Manual

Dual tech curtain intrusion detector
Table of Contents

Advertisement

Available languages

Available languages

PLASTIC ADAPTER
+
+
Note: You can request the sensor with the lens perpendicular orientation
see the picture above.
NOTE: do not cover, partially or completely, the field of vision of the detector
DIP-SWITCH
DIP 1
LED disable
DIP 2
1 pulse for alarm
DIP 3
2mt coverage
DIP 4
alarm from all direction
DIP 5
1 --> 2 alarm
* To use the directional system optimally, you need to be inserted into the lens on the pyroelectric element separator
(see figure) and install it paying attention to the direction selection (dip-swtch5)

4. INSTALLATION AND CONNECTION

Choose a suitable location, mount the sensor using the turrets tear to get the tamper protection.
The cable can go from a tiny hole next to the terminals, or if the section is very large, you can switch from the knock-out
(see figure below)
www.amcelettronica.com
FRESNEL LENS
2 2 2
OFF
LED enable
2 pulse for alarm
3.5mt coverage
Alarm from one direction* (not IMQ certified)
2 --> 1 alarm
DT16
4
59°
3
34.5°
2
11.5°
0
1
-11.5°
1
-34.5°
2
3
-59°
4
0
1
2
3
unit: meters
1
0
-2°
1
0
1
2
3
2
4
5
4
5
ON
installation instructions v1.3
1
2
3
4
5
1