The OS-360/365 is an hardwired outdoor backup siren combining a
loud acoustic siren with a flashing light. The high-powered flashing
light helps to locate the active siren.
Model OS-360 is equipped with a piezo-electric siren mainly
suitable for urban areas with a high building density. If necessary
another piezo-electric siren (ACM-OS360) can be used.
Model OS-365 is equipped with a magneto-dynamic horn siren
mainly suitable for family houses or for buildings with more space
around them.
Two tamper switches are built into the unit. They react to removing the
cover from the unit or removing the siren from the wall. The siren's
housing is made of mechanical, weather and UV-resistant plastic. The
circuit board is protected against air humidity by a double layer of
varnish.
Specification
Power supply
Current Consumption
Backup battery
Piezoelectric siren (OS-360) sound level
With second piezo-electric siren (ACM-OS360)
Electro-acoustic siren (OS-365) sound level
Siren timer
Flasher timer
60 minutes / continuously
Resistance of the tamper loop in stand-by
Enclosure
Security grade 3 (with internal cover)
Security grade 2 (without internal cover)
Environmental class IV
Dimensions
Hereby, Jablotron Ltd., declares that this OS-360/OS-365 is in
compliance with the essential requirements and other relevant provisions
of 73/23/EC Low Voltage Directive and 89/336/EC EMC Directive.
Original of the conformity assessment can be found at the web page
www.jablotron.com, section Technical support.
.
Installation
The siren should be fixed to a place which is not easily accessible,
and protected against direct rain, if possible. It is recommended to
place the siren in visible places to discourage criminals. It is also an
advantage if the flashing light can be seen from a distance to help the
police or security guards with locating the active siren.
Do not place the siren near eaves where ice could form in winter.
Remove the plastic cover by removing the two screws (under
plastic caps) with a screwdriver
Route all cabling into the siren through the desired hole on the
rear part
Fix the siren in the desired place by hanging the siren housing on
the top screw and fix it using two other screws.
Connect the wires from the control panel to the siren (see the
examples of connections on Picture 2).
Fix the cable using the plastic holder which is to the left of the
board
Connect the back-up battery
Assemble the siren and tighten the screws
Insert the plastic caps onto the screws
Please keep in mind the high acoustic power of the siren and
protect your hearing during testing.
The OS-360/365 outdoor siren
The OS-360/365 outdoor siren
10 to 17 V DC
< 50 mA / 12 V
NiCd pack 4.8 V / 1800 mAh
Lifetime approx. 3 years
113 dB /1 m
118 dB /1 m
110 dB /1 m
5 minutes
(depending on the FLA input activation)
< 70 Ω
IP 34D
EN 50131-1
EN 50131
-25 to +60°C
230 x 158 x 75 mm
The terminal block connections
power voltage (+10 to 17V)
+12V -
GND – ground
Power supply voltage drops cause the siren and the flasher to activate.
SIR - disconnection from GND will cause activation of the siren.
FLA – disconnection from GND will cause activation of the flasher.
ARM – a terminal for additional features. Its function depends on the
setting of the CHIRP and FLASH jumpers (see table 2).
NC tamper switch output (connected in series with the
TMP, TMP -
68R protection resistor)
There are also NiCd backup battery and siren connectors. The NiCd
backup battery comes from the factory disconnected. Only connect it
during installation.
terminal
LED flash light
Picture 1 the top side of the electronic circuit board
Terminals ARM, FLA and SIR can also be used for the remote
measurement of the backup battery voltage without the necessity of
climbing up to the siren. Measurement is always made on a single
disconnected cable against GND, directly in the control panel – see
Table 1.
ARM disconnected
Voltage of the charging battery
FLA
Flasher activated – battery is loaded by 100mA
disconnected
SIR
Siren activated – battery is loaded by 1A
disconnected
The setting jumpers
There are three jumpers on the PCB (Picture 1 shows their location)
to select the optional functions:
ON - one chirp on connecting ARM to GND, and 2
CHIRP
chirps sound on disconnecting from GND
OFF – chirps are disabled
ON - flashing for 60 minutes after siren deactivation
(connection of FLA to GND)
Any change on the ARM line will terminate flashing
FLASH
immediately
OFF - flashing is terminated immediately when FLA
is connected to GND
ON the siren flashes
OK
(confirmation of readiness)
OFF – indication is disabled
1
siren connector
setting jumpers
battery connector
Table 1
once every 45 sec.
Table 2
tampers
MGZ 51203

Advertisement

loading

Summary of Contents for jablotron OS-360

  • Page 1 The OS-360/365 outdoor siren The OS-360/365 is an hardwired outdoor backup siren combining a The terminal block connections loud acoustic siren with a flashing light. The high-powered flashing light helps to locate the active siren. power voltage (+10 to 17V)
  • Page 2 In this configuration the siren and the flasher are activated during an alarm from the control panel. Arming and disarming are confirmed by chirps. The following conditions are necessary for the OS-360/365 to be Flashing is terminated immediately after disarming the control panel ready: regardless of the setting of the FLASH jumper.

This manual is also suitable for:

Os-365