Bosch BMAC2430ANTD Installation Manual page 7

Multi-position cased coils cooling and heat pump compatible
Table of Contents

Advertisement

Installation Manual
V APOR LINE CONNECTION
COPPER (SWE A T)
LIQUID LINE CONNECTION
AUXILIA RY DRAIN CONNECTION
3/4'' NP T FEMALE PIPE THREAD
Figure 4
Model
Unit Height "H"
BMAC4248BNTF
30 [762]
BMAC4248CNTF
30 [762]
BMAC4248DNTF
30 [762]
Table 2
Bosch Thermotechnology Corp. | 03.2017
T O P AIR S T O P
V APOR LINE CONNECTION
LIQUID LINE CONNECTION
AUXILIA R Y DRAIN CONNECTION
3/4'' NP T FEMALE PIPE THREAD
Dimensions inch [mm]
Unit Width "W"
Supply Duct "A"
17½ [445]
16 [407]
21 [533]
19½ [495]
24½ [622]
23 [584]
Bosch Multi-Position Cased Coils | 7
COI L ACCESS
P ANE L
PRIMA RY DRAIN
H
CONNETION
3/4'' NP T FEMALE
PIPE THREAD
AUXILIA RY DRAIN
CONNECTION
3/4'' NP T FEMALE
PIPE THREAD
PRIMA RY DRAIN CONNETION
3/4'' NP T FEMALE PIPE THREAD
"W1"
Liquid line /Vapor Line
16½ [419]
⅜ /⅞
20 [508]
⅜ /⅞
23½ [597]
⅜ /⅞
Weight /Shipping
(LBS [kg])
67.7/91.7[30.7/41.6]
71.4/99.9[32.4/45.3]
75.0/107.8[34.0/48.9]
Data subject to change