LG AB-H366GSA0 B36AH SG0 Product Data page 19

Ceiling concealed duct (50hz, r410a)
Table of Contents

Advertisement

50Hz • R410A • Heat Pump
50Hz • R410A • Heat Pump
• Cooling Capacity
Model
AB-H246HTA0[B24AHV SH0]
AFR
18
Indoor Air
Temperature
20
°CWB °CDB
TC
SHC
PI
14
20
5.5
4.0
1.6
16
22
6.4
4.5
1.7
18
25
7.1
4.9
1.7
19
27
7.4
5.1
1.7
22
30
8.2
5.4
1.7
24
32
8.5
5.5
1.8
Model
AB-H306GTA0[B30AHV SG0]
AFR
32
Indoor Air
Temperature
20
°CWB °CDB
TC
SHC
PI
14
20
7.6
6.1
2.2
16
22
8.9
6.9
2.2
18
25
9.9
7.6
2.2
19
27
10.4
7.8
2.3
22
30
11.4
8.3
2.3
24
32
11.8
8.4
2.3
Model
AB-H366GTA0[B36AHV SG0]
AFR
32
Indoor Air
Temperature
20
°CWB °CDB
TC
SHC
PI
14
20
8.1
6.5
2.3
16
22
9.4
7.4
2.3
18
25
10.5
8.1
2.3
19
27
11.0
8.3
2.4
22
30
12.1
8.8
2.4
24
32
12.5
9.0
2.4
• Symbol
AFR : Air flow rate
DB : Dry bulb temperature
WB : Wet bulb temperature
TC : Total capacity
SHC : Sensible capacity
PI : Power Input
(Comp.+ indoor fan motor+outdoor fan motor)
18
Ceiling Concealed Duct
Outdoor Air Temperature : °CDB
25
32
TC
SHC
PI
TC
SHC
5.4
4.0
1.9
5.1
3.9
6.2
4.5
2.0
5.9
4.4
7.0
4.9
2.0
6.6
4.7
7.3
5.0
2.0
6.9
4.9
8.0
5.3
2.1
7.6
5.2
8.3
5.4
2.1
7.9
5.2
Outdoor Air Temperature : °CDB
25
32
TC
SHC
PI
TC
SHC
7.4
6.1
2.6
7.1
5.9
8.7
6.9
2.6
8.3
6.7
9.7
7.5
2.6
9.2
7.2
10.1
7.7
2.7
9.7
7.5
11.1
8.2
2.7
10.6
7.9
11.6
8.3
2.8
11.0
8.0
Outdoor Air Temperature : °CDB
25
32
TC
SHC
PI
TC
SHC
7.9
6.5
2.7
7.5
6.3
9.2
7.3
2.7
8.8
7.1
10.3
8.0
2.8
9.8
7.7
10.8
8.2
2.8
10.3
8.0
11.8
8.7
2.8
11.3
8.4
12.3
8.9
2.9
11.7
8.5
[m
3
/min]
[°C]
[°C]
[kW]
[kW]
[kW]
35
PI
TC
SHC
PI
TC
2.3
4.9
3.8
2.4
4.8
2.3
5.8
4.3
2.4
5.6
2.3
6.4
4.6
2.5
6.2
2.4
6.7
4.8
2.5
6.5
2.4
7.4
5.0
2.5
7.1
2.4
7.7
5.1
2.6
7.4
35
PI
TC
SHC
PI
TC
3.0
6.9
5.8
3.1
6.6
3.0
8.0
6.5
3.2
7.7
3.1
9.0
7.1
3.2
8.6
3.1
9.4
7.3
3.3
9.0
3.2
10.3
7.7
3.3
9.9
3.2
10.7
7.8
3.4
10.3
35
PI
TC
SHC
PI
TC
3.1
7.3
6.2
3.3
7.0
3.2
8.5
7.0
3.3
8.2
3.2
9.5
7.5
3.4
9.2
3.3
10.0
7.8
3.5
9.6
3.3
10.9
8.2
3.5
10.5
3.4
11.3
8.3
3.5
10.9
• Notes
1. All capacites are net, evaporator fan motor heat is
deducted.
2.
Indicates nominal capacity.
3. Direct interpolation is permissible. Do not extrapolate
4. Capacities are based on the following conditions:
- Interconnecting Piping Length 7.5m
- Level Difference of Zero.
Performance Data
40
43
SHC
PI
TC
SHC
PI
3.7
2.5
4.7
3.6
2.6
4.2
2.6
5.4
4.1
2.7
4.5
2.6
6.1
4.4
2.7
4.7
2.7
6.3
4.6
2.7
4.9
2.7
7.0
4.8
2.8
5.0
2.7
7.2
4.9
2.8
40
43
SHC
PI
TC
SHC
PI
5.6
3.3
6.5
5.6
3.5
6.4
3.4
7.6
6.3
3.5
6.9
3.5
8.4
6.8
3.6
7.1
3.5
8.8
7.0
3.6
7.5
3.6
9.7
7.4
3.7
7.6
3.6
10.0
7.5
3.7
40
43
SHC
PI
TC
SHC
PI
6.0
3.5
6.9
5.9
3.6
6.8
3.6
8.0
6.7
3.7
7.4
3.6
9.0
7.2
3.7
7.6
3.7
9.4
7.5
3.8
8.0
3.7
10.3
7.9
3.8
8.1
3.8
10.7
8.0
3.9