3.7.3. Cancel of "Automatic Saving"
If "Timer" pad is pressed 5 times, following will be performed.
"Automatic" is displayed on LCD, and performs either mode of "Unused hours" or "Used hours".
Operation :
Press "Automatic Saving/Timer" pad.
Display
"Automatic" on LCD is erased.
If the water temperature is low when this function is cancelled, re-boiling will be started.
3.7.3.1. If reset the stored use pattern
Stored use pattern will be erased if the power plug is disconnected and left for more than 10 hours.
3.7.4. About storage of use pattern (hours using this unit and unused hours)
• Storage of use pattern (learning function) of "Automatic Saving" is made in the following procedure.
This function split a day (24 hours) into 72 pieces of time, each piece is 20 minutes, and store the record of used or unused of
each peace. Judgment method in this unit whether used or unused is as follows.
Regarded as "Used"
If the hot water is dispensed.
Regarded as "Unused"
Other cases such as boiling, keep warm, power supply is stopped by timer function, power supply is stopped by disconnection
of power plug etc.
Storage (learning) of basic use pattern
Basic use pattern means the operation pattern (Automatic Saving) applied to the operation of the days after 2nd week from
the date of first power on.
After the first power on, used hour (1 piece) during 1 week (7 days) are accumulated and stored. After the data for 1 week
is stored, a same time in a day is used at least 1 time, such period of time is deemed "used", and others are deemed "unused".
After 2nd week, pot is operated based on this pattern.
After 3rd week, data in 2nd week is reflected and update the basic pattern to follow the variation of life pattern.