IC1 RH-iX0001SJZZ: System Microcomputer (IX0001SJ) (2/2)
Pin No.
Port Name
48*
P66/DGT16
SW_RLAY
49
P65/DGT15
SPSWA
50*
P64/DGT14
SPSWB
51
P63/DGT13
PROTECT
52
P62/DGT12
FAN
53
P61/DGT11
LED1
54
P60/DGT9
1G
55
P41/DGT8
2G
56
P40/SEG0/DGT7
3G
57-63
P77/SEG1/DGT6-
4G-10G
P71/SEG7/DGT0
64
P70/SEG8
P1
65-72
P87/SEG8-
P2-P9
P80/SEG15
73-79
P97/SEG16
P10-P16
P91/SEG22
80*
P90/SEG23
N.C
81*-83* PC2/SEG24-
N.C
PC0/SEG26
84*
PB7/SEG27
DAPD
85*
PB6/SEG28
ADPD
86*
PB5/SEG29
AC3_RES
87*
PB4/SEG30
AC3_SS
88*
PB3/SEG31
AC3_SI
89*
PB2/SEG32
D_SEL
90*
PB1/SEG33
AC3_SCK
91*
PB0/SEG34
SW_ON
92
PD7/SEG35
PRO_ENA
93
PD6/SEG36
PRO_DI
94
PD5/SEG37
PRO_CK
95*,96* PD4/SEG38,
V_SW1,
PD3/SEG39
V_SW2
97
PD2/SEG40
V_MUTE
98*,99* PD1/SEG41,
DEM0,DEM1
100
VPP
VPP
In this unit, the terminal with asterisk mark (*) is (open) terminal which is not connected to the outside.
All manuals and user guides at all-guides.com
Input/
Terminal
Output
Name
Output
Woofer speaker protective relay control, output
"H" = RLAY CLOSE, "L" = RLAY OPEN
Input
Headphone plug insertion detection, input, and 'A' speakers' switch input
Input
'B' speakers' switch input
Input
power amplifier protect mode, input
Output
Air-cooling fan control, output
Output
Timer stand-by ON LED control, output
"L" = Timer OFF, "H" = Timer ON
Output
VFD grid output
Output
VFD grid output
Output
VFD grid output
Output
VFD grid output
Output
VFD anode output
Output
VFD anode output
Output
VFD anode output
—
Not used
—
Not used
Output
D/A convertor ON/OFF control, output
Output
A/D convertor ON/OFF control, output
Output
ZR38600 reset, output
Output
ZR38600 slave, output
Output
ZR38600 serial data, output
Output
Digital function input select terminal "L" = Digital 2, "H" = Digital 1
Output
Synchronous clock output to the ZR38600
Output
Sub woofer ON/OFF, output
Output
Pro Logic IC enable, output "L" = OFF, "H" = ON
Output
Data output to the Pro Logic IC
Output
Synchronous clock output to the Pro Logic IC
Output
Video input/output select switch control signal
Output
Video output mute signal
Output
D/A convertor de-emphasas filter control, output
—
Not used
Function
"L" = OFF, "H" = ON
– 25 –
HT-DP2500W
"L" = STANDBY, "H" = ON
"L" = STANDBY, "H" = ON