Symantec NetBackup 5000 Replacement Manual

Chassis replacement guide
Hide thumbs Also See for NetBackup 5000:

Advertisement

Quick Links

Symantec NetBackup 5000
Chassis Replacement Guide

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the NetBackup 5000 and is the answer not in the manual?

Questions and answers

Summary of Contents for Symantec NetBackup 5000

  • Page 1 Symantec NetBackup 5000 Chassis Replacement Guide...
  • Page 2 Corporation or its affiliates in the U.S. and other countries. Other names may be trademarks of their respective owners. This Symantec product may contain third party software for which Symantec is required to provide attribution to the third party (“Third Party Programs”). Some of the Third Party Programs are available under open source or free software licenses.
  • Page 3: Table Of Contents

    Contents Contents .............................. 2 Figures ..............................1 1 Replacing Parts ........................... 1-1 1.1 Overview ............................... 1-1 1.2 Obtaining IPMI settings on the original chassis .................... 1-2 1.3 Installing the IPMITOOL in a Windows PC ....................1-3 1.4 Removing and replacing a chassis ......................... 1-3 1.5 Configuring IPMI settings on the new chassis ....................
  • Page 4: Figures

    Figures Figure 1-1 IPMI IP address displayed on the system self-test page ..............1-2 Figure 1-2 Ipmitool Directory ..........................1-3 Figure 1-3 Pressing Del during the system self-check ..................1-5 Figure 1-4 Setting the IP address and subnet mask ..................... 1-5 Figure 1-5 Choosing Send to BMC ........................
  • Page 5: Replacing Parts

    Disconnect the NetBackup 5000 from the power sockets and external devices.  Turning off the NetBackup 5000 will affect any jobs or services that are running. Perform this operation with caution! Turn off the NetBackup 5000 before replacing the chassis; otherwise, the operations of the NetBackup 5000 may be affected.
  • Page 6: Obtaining Ipmi Settings On The Original Chassis

    1 minute. Otherwise, the IPMI IP address might not be display on the self-test screen. Step 2 Press the Power button on the rear of the cabinet to power on the NetBackup 5000. Step 3 On the system self-test page, the IPMI IP address is displayed, as shown in Figure 1-1.
  • Page 7: Installing The Ipmitool In A Windows Pc

    Disconnect the NetBackup 5000 from the power sources and peripheral equipment. Label all cables so that you can replace them in the same places in the new chassis. Step 4 Unscrew the chassis from the rack posts and smoothly pull the NetBackup 5000 out of the cabinet. Step 5...
  • Page 8: Configuring Ipmi Settings On The New Chassis

    1.5 Configuring IPMI settings on the new chassis Step 1. Press the Power button on the rear of the cabinet to turn on the NetBackup 5000. Step 2. During the system self-check, press Del to enter the BIOS interface, as shown in the...
  • Page 9: Figure 1-3 Pressing Del During The System Self-Check

    Figure 1-3 Pressing Del during the system self-check Step 3. On the BIOS interface, choose the IPMIBoot tab, as shown in Figure 1-4. Step 4. On the IPMIBoot tab page, set the same IP address and subnet mask as in the original chassis.
  • Page 10: Figure 1-5 Choosing Send To Bmc

    Figure 1-5 Choosing Send to BMC Step 6. Choose the Exit tab. Step 7. On this tab page, choose Save Changes and Exit and press Enter, as shown in Figure 1-6. Figure 1-6 Choosing Save Changes and Exit. Step 8. Login to the IPMI CLI with a Windows PC.
  • Page 11: Figure 1-7 Running The Upgrade.exe Command

    Go to the IPMI management interface and type "4" for choosing expander card debug port, as shown in Figure 1-8. The NetBackup 5000 has four options under Welcome to BMC SOL. Typing "4" will not echo in the screen. Figure 1-8 Options under Welcome to BMC SOL Step 11.
  • Page 12: Self-Test

    Typing "zone 3" will not echo in the screen. Figure 1-10 Modifying the zone setting You must take measures for the modification to take effect. Step 13. Press the Power button on the rear of the NetBackup 5000. Step 14. Remove the power cable Step 15.
  • Page 13: Figure 1-12 Yast Control Center

    Figure 1-12 YaST control center Use the arrow keys to locate System and Date and Time, and then press Enter. Figure 1-13 Selecting Date and Time On the Clock and Time Zone interface, Under Time and Date, select Change …, and then press Enter.
  • Page 14: Figure 1-14 Setting The Time Zone

    Figure 1-14 Setting the time zone In the Change System Date and Time interface, set the date and time as required, click Apply, and then press Enter. Figure 1-15 Setting the date and time In the Clock and Time Zone interface, select Accept, and then press Enter. 1-10...
  • Page 15: Figure 1-16 Confirming The Changes

    Figure 1-16 Confirming the changes Quit the YaST control center. Type the following commands to setup IPMI time: service ipmi start ipmitool sel time set "`date "+%m/%d/%Y %k:%M:%S"`" Type yast at the command prompt to start the YaST control center. 10.
  • Page 16: Figure 1-18 Select Network Card

    Figure 1-19 Edit network card IP address 13. Select Quit. 14. If the system has been configured with bonding, bind the NIC again to use the base- board network interface. 15. Run the reboot command to reboot the NetBackup 5000. 1-12...
  • Page 17 1-13...

Table of Contents