Page 2
Corporation or its affiliates in the U.S. and other countries. Other names may be trademarks of their respective owners. This Symantec product may contain third party software for which Symantec is required to provide attribution to the third party (“Third Party Programs”). Some of the Third Party Programs are available under open source or free software licenses.
Contents Contents .............................. 2 Figures ..............................1 1 Replacing Parts ........................... 1-1 1.1 Overview ............................... 1-1 1.2 Obtaining IPMI settings on the original chassis .................... 1-2 1.3 Installing the IPMITOOL in a Windows PC ....................1-3 1.4 Removing and replacing a chassis ......................... 1-3 1.5 Configuring IPMI settings on the new chassis ....................
Figures Figure 1-1 IPMI IP address displayed on the system self-test page ..............1-2 Figure 1-2 Ipmitool Directory ..........................1-3 Figure 1-3 Pressing Del during the system self-check ..................1-5 Figure 1-4 Setting the IP address and subnet mask ..................... 1-5 Figure 1-5 Choosing Send to BMC ........................
Disconnect the NetBackup 5000 from the power sockets and external devices. Turning off the NetBackup 5000 will affect any jobs or services that are running. Perform this operation with caution! Turn off the NetBackup 5000 before replacing the chassis; otherwise, the operations of the NetBackup 5000 may be affected.
1 minute. Otherwise, the IPMI IP address might not be display on the self-test screen. Step 2 Press the Power button on the rear of the cabinet to power on the NetBackup 5000. Step 3 On the system self-test page, the IPMI IP address is displayed, as shown in Figure 1-1.
Disconnect the NetBackup 5000 from the power sources and peripheral equipment. Label all cables so that you can replace them in the same places in the new chassis. Step 4 Unscrew the chassis from the rack posts and smoothly pull the NetBackup 5000 out of the cabinet. Step 5...
1.5 Configuring IPMI settings on the new chassis Step 1. Press the Power button on the rear of the cabinet to turn on the NetBackup 5000. Step 2. During the system self-check, press Del to enter the BIOS interface, as shown in the...
Figure 1-3 Pressing Del during the system self-check Step 3. On the BIOS interface, choose the IPMIBoot tab, as shown in Figure 1-4. Step 4. On the IPMIBoot tab page, set the same IP address and subnet mask as in the original chassis.
Figure 1-5 Choosing Send to BMC Step 6. Choose the Exit tab. Step 7. On this tab page, choose Save Changes and Exit and press Enter, as shown in Figure 1-6. Figure 1-6 Choosing Save Changes and Exit. Step 8. Login to the IPMI CLI with a Windows PC.
Go to the IPMI management interface and type "4" for choosing expander card debug port, as shown in Figure 1-8. The NetBackup 5000 has four options under Welcome to BMC SOL. Typing "4" will not echo in the screen. Figure 1-8 Options under Welcome to BMC SOL Step 11.
Typing "zone 3" will not echo in the screen. Figure 1-10 Modifying the zone setting You must take measures for the modification to take effect. Step 13. Press the Power button on the rear of the NetBackup 5000. Step 14. Remove the power cable Step 15.
Figure 1-12 YaST control center Use the arrow keys to locate System and Date and Time, and then press Enter. Figure 1-13 Selecting Date and Time On the Clock and Time Zone interface, Under Time and Date, select Change …, and then press Enter.
Figure 1-14 Setting the time zone In the Change System Date and Time interface, set the date and time as required, click Apply, and then press Enter. Figure 1-15 Setting the date and time In the Clock and Time Zone interface, select Accept, and then press Enter. 1-10...
Figure 1-16 Confirming the changes Quit the YaST control center. Type the following commands to setup IPMI time: service ipmi start ipmitool sel time set "`date "+%m/%d/%Y %k:%M:%S"`" Type yast at the command prompt to start the YaST control center. 10.
Figure 1-19 Edit network card IP address 13. Select Quit. 14. If the system has been configured with bonding, bind the NIC again to use the base- board network interface. 15. Run the reboot command to reboot the NetBackup 5000. 1-12...