Advertisement

Quick Links

Copyright 1997 Sun Microsystems, Inc., 901 San Antonio Road • Palo Alto, CA 94303 USA. All rights reserved.
This product or document is protected by copyright and distributed under licenses restricting its use, copying, distribution, and decompilation. No
part of this product or document may be reproduced in any form by any means without prior written authorization of Sun and its licensors, if any.
Third-party software, including font technology, is copyrighted and licensed from Sun suppliers.
Parts of the product may be derived from Berkeley BSD systems, licensed from the University of California. UNIX is a registered trademark in the
U.S. and other countries, exclusively licensed through X/Open Company, Ltd.
Sun, Sun Microsystems, the Sun logo, AnswerBook, SunDocs, and Solaris are trademarks, registered trademarks, or service marks of Sun
Microsystems, Inc. in the U.S. and other countries. All SPARC trademarks are used under license and are trademarks or registered trademarks of
SPARC International, Inc. in the U.S. and other countries. Products bearing SPARC trademarks are based upon an architecture developed by
Sun Microsystems, Inc.
The OPEN LOOK and Sun™ Graphical User Interface was developed by Sun Microsystems, Inc. for its users and licensees. Sun acknowledges
the pioneering efforts of Xerox in researching and developing the concept of visual or graphical user interfaces for the computer industry. Sun
holds a non-exclusive license from Xerox to the Xerox Graphical User Interface, which license also covers Sun's licensees who implement OPEN
LOOK GUIs and otherwise comply with Sun's written license agreements.
DOCUMENTATION IS PROVIDED "AS IS" AND ALL EXPRESS OR IMPLIED CONDITIONS, REPRESENTATIONS AND WARRANTIES, INCLUDING
ANY IMPLIED WARRANTY OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE OR NON-INFRINGEMENT, ARE DISCLAIMED,
EXCEPT TO THE EXTENT THAT SUCH DISCLAIMERS ARE HELD TO BE LEGALLY INVALID.
Please
Recycle

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Ultra 60 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Sun Microsystems Ultra 60 Series

  • Page 1 Sun Microsystems, Inc. The OPEN LOOK and Sun™ Graphical User Interface was developed by Sun Microsystems, Inc. for its users and licensees. Sun acknowledges the pioneering efforts of Xerox in researching and developing the concept of visual or graphical user interfaces for the computer industry. Sun holds a non-exclusive license from Xerox to the Xerox Graphical User Interface, which license also covers Sun’s licensees who implement OPEN...
  • Page 2: Table Of Contents

    Contents 1 Operating and Service Positions................... 6 2 Opening the System Unit ...................... 8 3 Installing DIMMs ........................10 4 Changing the RS-423/232 Jumpers ................... 14 5 Installing the Hard Disk Drive....................18 6 Installing the Diskette Drive or Accessory Device.............. 24 7 Installing the CD-ROM Drive or Tape Drive................
  • Page 3 Inhalt 1 Aufstellung bei Betrieb und Wartung ..................6 2 Öffnen der Systemeinheit...................... 8 3 Installieren der DIMMs ......................10 4 Umstecken der RS-423/232-Jumper................... 14 5 Installieren des Festplattenlaufwerks .................. 18 6 Installieren des Diskettenlaufwerks oder Zusatzgeräts ............24 7 Installieren des CD-ROM- oder Bandlaufwerks ..............30 8 Installieren von UPA-Grafikkarten oder PCI-Karten ............
  • Page 4 Innehåll 1 Lägen för drift och service ....................6 2 Öppna systemenheten ......................8 3 Installera DIMM-moduler ..................... 10 4 Ändra RS-423/232-byglarna....................14 5 Installera skivminnet ......................18 6 Installera diskettenheten eller tillbehörsenheten..............24 7 Installera CD-spelaren eller bandstationen................. 30 8 Installera UPA-grafikkort eller PCI-kort ................
  • Page 5 FCC radio frequency emission limits. Networking connections can be made using unshielded twisted-pair (UTP) cables. Modifications: Any modifications made to this device that are not approved by Sun Microsystems, Inc. may void the authority granted to the user by the FCC to operate this equipment.
  • Page 6 Dennis P. Symanski DATE John Shades DATE Manager, Product Compliance Quality Assurance Manager Sun Microsystems, Inc. Sun Microsystems Scotland, Limited 901 San Antonio Road Springfield, Linlithgow Los Altos, CA 94303, USA West Lothian, EH49 7LR Scotland, United Kingdom Tel.: 650-786-3255 Tel.: 0506 670000...
  • Page 7: Operating And Service Positions

    Operating and Service Positions Operating Position The Sun Ultra 60 system must be operated in a vertical position. Service Position Place the system in the horizontal service position on a hard surface to perform service on the system. Aufstellung bei Betrieb und Wartung In Betrieb Zum Betrieb muß...
  • Page 9: Opening The System Unit

    Opening the System Unit 1. Press the Standby ( ) side of the power switch. 2. Remove the lock block from the system. 3. Grasp the side panel and pull it toward the back of the system. Lift up and remove the panel. Öffnen der Systemeinheit 1.
  • Page 11: Installing Dimms

    Installing DIMMs supply partially out until it is not blocking the DIMMs. Note — Use only dual in-line memory modules (DIMMs) that are 4. Locate and select an available bank of DIMM slots on the specifically designed for your Sun Ultra 60 system. See ( 11).
  • Page 13 Installing DIMMs 5. Unpack the DIMM, holding it only by the edges. 6. For each DIMM, align the notch on the side of the DIMM with the ejector on the DIMM slot. Insert the DIMM into the slot. 7. Push the DIMM firmly into its connector until you hear a “click.” 8.
  • Page 15: Changing The Rs-423/232 Jumpers

    Changing the RS-423/232 Jumpers 3. Use a Phillips screwdriver to loosen the four screws that hold Note — If you are connecting your system to a public X.25 network, the power supply to the chassis. Slide the power supply partially you may need to change the serial port mode jumpers from RS-423 out such that it is not blocking the jumpers.
  • Page 17 Changing the RS-423/232 Jumpers 4. Locate the jumpers on the motherboard ( 12). Change the jumpers on J2605 and J2604 to the RS-232 position. 5. Slide the power supply back into the chassis. Use a Phillips screwdriver to tighten the four screws that attach the power supply to the chassis.
  • Page 18 RS-232 RS-232...
  • Page 19: Installing The Hard Disk Drive

    Installing the Hard Disk Drive Note — Use only hard disk drives that are specifically designed for a Sun Ultra 60 system. 1. Power off the system and open the system unit ( 2. Locate the wrist strap, and attach its adhesive copper strip to the chassis back panel.
  • Page 21 Installing the Hard Disk Drive 4. Remove the hard disk drive from the antistatic bag. Read the hard disk drive product guide for information about jumper switch settings or other installation tasks. Installieren des Festplattenlaufwerks 4. Nehmen Sie das Festplattenlaufwerk aus der Antistatikhülle heraus.
  • Page 23 Installing the Hard Disk Drive 5. Open the drive handle and slide the drive completely into the drive bay. Press the drive to connect it to the SCSI port in the system. 6. Close the drive handle. The handle will not latch if the drive is not properly attached or closed.
  • Page 25: Installing The Diskette Drive Or Accessory Device

    Installing the Diskette Drive or Accessory Device 1. Power off the system and open the system unit ( 4. Use a Phillips screwdriver to loosen the two screws holding the removable media assembly (RMA) to the system chassis. 2. Locate the wrist strap, and attach its adhesive copper strip to the chassis back panel.
  • Page 27 Installing the Diskette Drive or Accessory Device 6. Remove the metal filler panel from the RMA. 8. Use a Phillips screwdriver to attach the diskette drive or accessory device to the RMA using the four screws provided. 7. Remove the diskette drive or accessory device from the antistatic bag.
  • Page 29 Installing the Diskette Drive or Accessory Device 10. Attach the power connector labeled P2 to the drive. Note — Steps 9 and 10 apply only to a diskette drive. If you are 11. Slide the RMA into the chassis. Tighten the two screws holding installing an accessory device, see its product guide for specific the RMA to the system.
  • Page 31: Installing The Cd-Rom Drive Or Tape Drive

    Installing the CD-ROM Drive or Tape Drive 1. Power off the system and open the system unit ( 3. Remove the peripheral bezel from the front of the system unit. 2. Locate the wrist strap, and attach its adhesive copper strip to 4.
  • Page 33 Installing the CD-ROM Drive or Tape Drive 5. Slide the RMA out of the system. 6. Remove the metal filler panel from the RMA. 7. Remove the drive from the antistatic bag. Read the drive product guide for information about jumper switch settings or any other installation tasks.
  • Page 35 Installing the CD-ROM Drive or Tape Drive 8. Use a Phillips screwdriver to attach the drive to the RMA using 10. Complete sliding the RMA into the chassis. Tighten the two the four screws provided. screws holding the RMA to the system chassis. 9.
  • Page 37: Installing Upa Graphics Cards Or Pci Cards

    Installing UPA Graphics Cards or PCI Cards 3. Remove the filler panel from the back panel of the system Note — If you are installing a PCI card, first see ( 13). chassis. 4. Fit the card back panel into one of the system chassis card 1.
  • Page 39 Installing UPA Graphics Cards or PCI Cards 5. Push the card by its corners straight down into the slot until the card is fully seated. You should hear two “clicks.” 6. Use a magnetized Phillips screwdriver to attach the card bracket tab to the system chassis.
  • Page 41: Installing Cpu Modules

    Installing CPU Modules 1. Power off the system and open the system unit ( 2. Locate the wrist strap, and attach its adhesive copper strip to the chassis back panel. Wrap the other end twice around your wrist, with the adhesive side against your skin. 3.
  • Page 43 Installing CPU Modules 4. Lower the CPU module along the vertical plastic guides until the module touches the motherboard slot socket. 5. With both hands, simultaneously turn and press the levers downward to the fully horizontal position. Firmly press the module downward into the socket until it is fully seated and the levers are fully locked.
  • Page 45: Closing The System Unit

    Closing the System Unit 1. Holding the side panel in both hands, guide it so that the hooks align with the channels on the system unit chassis. Align the alignment dots on the cover and system top before sliding the cover forward.
  • Page 47: Dimm Installation Guidelines

    DIMM Installation Guidelines • Ultra 60 DIMMs are installed in banks of four. Note — See ( 12) for additional DIMM installation information. • Each bank of four DIMMs must be of the same memory size and speed. • To boot, the system must have a minimum of four DIMMs in a bank of mapped slots.
  • Page 49: Dimm Banks And Slot Pairs

    DIMM Banks and Slots Bank: Slots: U1001, U1002, U1003, U1004 U0901, U0902, U0903, U0904 U0801, U0802, U0803, U0804 U0701, U0702, U0703, U0704 DIMM-Bänke und Steckplatzpaare Bank: Steckplatzpaar: U1001, U1002, U1003, U1004 U0901, U0902, U0903, U0904 U0801, U0802, U0803, U0804 U0701, U0702, U0703, U0704 DIMM-bankar och modulplatser Bank: Modulplatser:...
  • Page 50 J2703 U1004 U1003 U1002 U1001 U0904 U0903 U0902 U0901 U0804 U0803 U0802 U0801 U0704 U0703 U0702 U0701 J0101 J0201 J1301 J1401 J1501 J1601...
  • Page 51: Pci Card Slot Operating Frequencies

    PCI Card Slot Operating Frequencies • All Sun Ultra 60 system PCI card slots operate at 32-bit or 64-bit bus widths. Operating Input/Output Card Slot: Frequency: Signaling Level: • Most PCI cards operate at 33 MHz. Slot 1 J1301 33 MHz or 66 MHz 3.3 volts •...
  • Page 52 J1301 J1401 J1501 J1601...
  • Page 53: What's Next

    What’s Next After you have installed all internal options and made modifications For more information, refer to: to the system, you are ready to have a system administrator install Sun Ultra 60 Hardware Setup Instructions the Solaris software. Refer to the SMCC SPARC Hardware Platform Sun Ultra 60 Product Notes Guide .
  • Page 55: Safety Agency Compliance

    Do not make mechanical or electrical modifications to the parts. They may explode if mistreated.Do not dispose of the equipment. Sun Microsystems is not responsible for regulatory battery in fire. Do not disassemble it or attempt to recharge compliance of a modified Sun product.
  • Page 56 System Unit Cover You must remove the cover of your Sun computer system unit in order to add cards, memory, or internal storage devices. Be sure to replace the top cover before powering up your computer system. Caution – Do not operate Sun products without the top cover in place.
  • Page 57: Einhaltung Der Sicherheitsvorschriften

    Netzkabel nicht an, wenn das Netzteil aus der Geräten. Systemeinheit entfernt wurde. Änderungen an der Ausrüstung Nehmen Sie keine mechanischen oder elektrischen Änderungen an den Geräten vor. Sun Microsystems übernimmt bei einem Sun- Produkt, das geändert wurde, keine Verantwortung für die Einhaltung behördlicher Vorschriften.
  • Page 58 Lithiumbatterie Achtung – CPU-Karten von Sun verfügen über eine Echtzeituhr mit integrierter Lithiumbatterie (Teile-Nr. MK48T59Y, MK48TXXB-XX, MK48T18-XXXPCZ, M48T59W-XXXPCZ oder MK48T08). Diese Batterie darf nur von einem qualifizierten Servicetechniker ausgewechselt werden, da sie bei falscher Handhabung explodieren kann. Werfen Sie die Batterie nicht ins Feuer. Versuchen Sie auf keinen Fall, die Batterie auszubauen oder wiederaufzuladen.
  • Page 59: Säkerhetsföreskrifter

    Säkerhetsföreskrifter Det här avsnittet innehåller de säkerhetsföreskrifter som du bör Varning – Blockera eller täck inte över öppningarna på iaktta när du installerar produkter från Sun Microsystems. utrustningen. Du får inte heller placera den nära element Regler eller andra värmekällor. Följ dessa regler för att försäkra dig om att Sun-utrustningen fungerar säkert och inte blir...
  • Page 60 Öppna systemenheten Norge Du måste öppna systemenheten om du ska installera kort, ADVARSEL – Litiumbatteri — Eksplosjonsfare. minnesmoduler eller interna minnesenheter. Kontrollera att du har Ved utskifting benyttes kun batteri som anbefalt av monterat ihop systemenheten rätt innan du kopplar på strömmen apparatfabrikanten.
  • Page 61 © 1997 Sun Microsystems, Inc. 901 San Antonio Road • Palo Alto, © 1997 Sun Microsystems, Inc. 901 San Antonio Road • Palo Alto, California 94303-4900 USA. Alle Rechte vorbehalten. California 94303-4900 USA. Alla rättigheter förbehålles. Dieses Produkt und diese Dokumentation sind durch Copyright Denna produkt och tillhörande dokumentation är copyright-skyddad.

Table of Contents