► 1. Latch lever 2. Door 3. Magazine cap
3.
Turn the adjust shaft and set the step of the
change plate suitable for the nail length. Make sure that
the arrow points to the corresponding graduation incre-
ment of the nail length marked on the adjust shaft.
2
► 1. Change plate 2. Adjust shaft 3. Arrow
NOTICE:
If the tool is operated with the change
plate set to the wrong step, it may result in poor nail
feeding or tool malfunction.
4.
Place the nail coil over the change plate and
uncoil enough nails to reach the nail rail.
Then place the first nail in the nail rail and the second
nail in the feed claw. Also, place other uncoiled nails on
feeder body.
1
3
2
3
1
2
1
► 1. Nail rail 2. Feed claw
5.
Check that the nail coil is set properly in the
magazine.
6.
Close the magazine cap carefully. Then with
depressing the latch lever, close the door until the latch
lever locks.
Connecting air hose
CAUTION:
Do not connect the air hose with
a finger on the trigger. An unexpected driving will
cause serious injury.
► 1. Air fitting 2. Air socket
Slip the air socket of the air hose onto the air fitting on
the nailer. Be sure that the air socket locks firmly into
position when installed onto the air fitting.
A hose coupling must be installed on or near the tool in
such a way that the pressure reservoir will discharge at
the time the air supply coupling is disconnected.
Changing the trigger for contact
actuation mode
CAUTION:
Always disconnect the air hose
and unload the tool with nails before replacing
the trigger.
CAUTION:
After the trigger replacement,
always check that the tool operates properly
before actual work. Do not load the tool with any
nails before checking the function to avoid unex-
pected nailing.