Partial Activation Mode "Part 1; Partial Activation Modes "Part 2" And "Part 3; Excluding Certain Zones From; The Alarm Recording - Monacor security DA-8000 Instruction Manual

8-loop alarm control system with lcd keypad controller
Hide thumbs Also See for security DA-8000:
Table of Contents

Advertisement

Available languages

Available languages

As soon as the alarm control system is activated,
the display changes to:
21 Jun 18:05
<<<
SET
Notes
1.
To activate the alarm control system within the
next three seconds (still before the end of exit
delay) the button Quick can be pressed (e. g. after
exiting the last "E/E" zone).
2.
For interrupting the activation process during the
exit delay, enter a corresponding access code.

3.2 Partial activation mode "Part 1"

In this mode the alarm zones are excluded from an
alarm triggering for which the mode "Part 1", "Ch/P1",
"Part 3", or "Ch/P3" has been programmed (if neces-
sary, see overview on the last page).
1) If the function for quick activation is possible (if
necessary, see overview on the last page), press
the button Quick. If not, enter a valid access code.
2) Actuate the button Part.
3) The signal for the run of the exit delay time sounds
and the display shows in the meantime:
Exit Now!...
O k !
As soon as the alarm control system is activated,
the display changes to:
22 Jun 16:12
<<<
SET 1 >>>
Notes: see chapter 3.1.

3.3 Partial activation modes "Part 2" and "Part 3"

In the mode "Part 2" the alarm zones are excluded
from an alarm triggering for which the mode "Part 2",
"Part 3", "Ch/P2", or "Ch/P3" has been programmed (if
necessary, see overview on the last page).
In the mode "Part 3" the alarm zones are excluded
from an alarm triggering for which the mode "Part 1",
"Part 2", "Part 3", "Ch/P1", Ch/P2", or "Ch/P3" has
been programmed (if necessary, see overview on the
last page).
1) If the function for quick activation is possible (if
necessary, see overview on the last page), press
the button Quick. If not, enter a valid access code.
2) Actuate the button Part.
3) In addition press the numerical key 2 for the mode
"Part 2" or the numerical key 3 for the mode
"Part 3". The signal for the run of the exit delay
time sounds and the display shows in the mean-
time:
Exit Now!...
O k !
As soon as the alarm control system is activated,
with mode "Part 2" the display changes to:
>>>
1
2
22 Jun 16:12
<<<
SET 2 >>>
In the mode "Part 3" the display shows:
22 Jun 16:12
<<<
SET 3 >>>
Notes: see chapter 3.1.
3.4 Excluding certain zones from the alarm
recording
Certain zones, e. g. in which the work is not yet termi-
nated, can be excluded from the recording so that the
alarm control system can be activated in spite of this
and takes over the surveillance of the other zones.
1) The alarm control system must be deactivated.
Then the display shows:
21 Jun 17:53
<<<
UNSET
2) Enter a valid master access code (user numbers 1
to 3) with the numerical keys (e. g. that of the
default setting 5, 6, 7, 8). The display shows:
Do You Want to..
Set User 1 ?
3) Press the button No within 15 seconds, otherwise
the menu will be exited. The display shows:
Do You Want to..
Test ?
4) Press the button No again. The display shows:
Do You Want to..
Delete Zone ?
5) Now press the button Yes. The display shows:
Enabled Zones...
12345678
In the second line of the display the zones are indi-
cated which are active with the alarm control
system activated.
6) Successively press the numerical keys which cor-
respond to the zones to be deactivated, e. g.:
Enabled Zones...
-234--78
7) A zone which is not selected any more can be se-
lected again by pressing the corresponding nu-
merical key once more.
8) After the selection press the button 0 twice so that
the display e. g. shows:
Do You Want to..
Set User 1
9) Now activate the alarm control system with the fol-
lowing buttons within 15 seconds:
Full for the full activation mode or
Part for the partial activation mode 1 or
Part and 2 for the partial activation mode 2 or
Part and 3 for the partial activation mode 3
>>>
?
GB