Detached External Temperature Sensor Error - Samsung AF28FVSDA N Series Service Manual

Floor stand type air conditioner
Hide thumbs Also See for AF28FVSDA N Series:
Table of Contents

Advertisement

4-4-14 Detached external temperature sensor error

Indoor unit display
Outdoor unit display
1. Cause of malfunction
1) Sensor detached from sensor holder
2) Sensor detached from outdoor unit PBA connector
3) Faulty sensor itself
4) Problematic outdoor unit PBA
2. Check procedure
1) Check to see if temperature sensor is attached properly to the sensor holder
2) Check to see if temperature sensor is connected properly to the outdoor unit PBA connector
Samsung Electronics
(Detached external COND temperature sensor error)
(Detached external DISCHARGE temperature sensor error)
○(YEL) ◎(GRN) ●(RED)
Troubleshooting
4-23

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents