Control Box Installation - Wayne WSS30Vn Operating Instructions And Parts Manual

Submersible sump pump system
Table of Contents

Advertisement

Operating Instructions and Parts Manual
AC PUMP CHECK
1. Fill the basin/pit with water. The pump will start when the
water level has reached the float switch-on level.
2. The pump will stop when the water level has reached the
switch-off level.
3. Verify the switch is operating without any obstruction from
the pump, piping and basin.
4. Fill the basin/pit with water again. While the system is
draining the basin/pit, verify the discharge pipe is carrying
the water to a point at least 3 ft. away from the foundation.
If the discharge line is exposed to freezing temperatures,
the pipe must be positioned in a downward slope away
from the foundation so any remaining water will drain away
and not freeze.

CONTROL BOX INSTALLATION

1. Place battery in box, attach red cable to positive battery
post and black cable to negative battery post.
If cables are reversed, damage to the control box or
battery will result, and void warranty.
MISE EN GARDE
Si les câbles sont inversés, la boîte de
contrôle ou la batterie pourrait être endommagée et la garantie annulée.
2. Plug the float pump system and transformer into the
appropriate connectors. The connections are all unique
and cannot be interchanged.
6
FLOOR JOIST
CONNECTOR
45º elbow
TRANSFORMER
REQUIRED
CHECK VALVE
(SEE STEP 3 & 7)
BATTERY BOX
FLOAT SWITCH
BACKUP DC PUMP
Figure 2 - Method 2
3. Put lid on box, and place the battery within six feet of the
sump and a 115 VAC separately fused outlet. The
outlet must be protected by a ground fault circuit
interrupter (GFCI) The area must also be clean, dry and
well ventilated.
Do not allow battery box to get wet, or expose it to
moisture. Electronics will be damaged and void warranty.
MISE EN GARDE
Ne pas laisser le coffre de la batterie
être mouillé ou exposé à l'humidité. Les appareils électroniques seront
endommagés et la garantie sera annulée.
BACK UP PUMP CHECK
1. Test system operation by filling the sump with water
while the main pump is unplugged. If the pump operates
properly, plug the transformer into the GFCI protected
outlet to begin charging the battery.
2. Protect electrical cord from sharp objects, hot surfaces,
oil and chemicals. Avoid kinking the cord.
3. Secure power supply cord to discharge pipe using cable or
zip ties to prevent possible switch entanglement.
SLOPE
PIPE
DOWN
"Y"
REQUIRED
CHECK VALVE
(SEE STEP 3)
RIGID
PVC
PIPE
PRIMARY AC PUMP
www.waynepumps.com