Extractor Installation Procedure
Caution
If this equipment is used in a manner not specified by the manufacturer, the
protection provided by the equipment may be impaired.
Read all instructions in this manual before using this extractor.
1. Move the unit to the location where it is going to be installed and remove the unit
from its packaging. The unit should be installed in a well ventilated room.
Caution
Due to the weight involved the extractor unit should only be lifted using suitable lifting
equipment and with regard to appropriate safety precautions. (See Appendix for
product weight details).
2. Ensure that a 0.5m space is available around any louvered areas of the unit to
ensure adequate air flow. Lock the two braked castors, if fitted.
Caution
Do not block or cover the cooling vents on the unit, as this severely restricts airflow
and may cause damage to the unit. (This may be located on the base of the unit).
Caution
Under no circumstances should the exhaust outlet/s be covered as this will restrict
the airflow and cause overheating.
3. Check filters are located in their correct position and carefully replace lid/close
door.
4. Connect the extraction ducting between the extractor inlet and the fume capture
device as detailed previously.
Optional Feature Considerations
5. If fitted, the following features need to be considered when installing the unit:
8
Version 1 Oct 2009
Need help?
Do you have a question about the AD ORACLE and is the answer not in the manual?
Questions and answers
BOFA AD Oracle.IQ
The BOFA AD Oracle iQ is a high-performance laser fume extraction system designed to remove harmful fumes during laser processes. It features the iQ Operating System, which offers real-time information, performance analytics, and enhanced safety. The unit includes a 12 m² pre-filter and 15 kg of activated carbon for effective filtration. It has a capacity of 380 m³/hr, uses a centrifugal fan, and operates at noise levels below 60 dB. The system is compact, measuring 980mm x 430mm x 430mm, and weighs 75 kg. It supports 115–230V single-phase power and is designed to minimize maintenance and operating costs.