How to use

Preparing the treatment area
Remove any visible hair on the skin before using the device. You may use your preferred hair removal
method. To keep the treatment window clean and intact, ensure there is no hair remaining on the skin
surface. Clean the treatment area and pat it dry.
To power on the device:
Use the mains cord (8) to connect the base station to an electrical outlet. Press the gentle mode button (4)
to activate the device. The LED power bars (3) will light up once and, a fan starts running. This means the
device is in READY mode. During operation, the device will heat up slightly.
Automatic light adaptation
When both skin tone sensors (2) have skin contact, the device reads your skin tone and selects the
appropriate light intensity which is indicated by white LEDs on the Power bars (3). These confirm that the
device is ready to flash.
Gentle mode
Push the gentle mode button (4) to reduce the light intensity. The gentle mode indicator lights up when it is
activated. To deactivate it, press the gentle mode button again.
The power bars flash to confirm a change in the light intensity setting.
When holding the gentle mode button (4) longer than 3 seconds, the device is deactivated.
After 10 minutes without use, the device is automatically deactivated.
To reactivate it, press the gentle mode button.
Patch Test
Before your first treatment, we recommend you test your skin for reaction to Braun Silk·expert on a small
area of skin of the body part you plan to treat (about 2 x 3 cm in size; equivalent to the size of two flashes,
side by side).
Perform a patch test as described below in chapter «Treatment methods», section «STAMPING».
Wait 48 hours to examine the test area. If the skin appears normal, begin your first treatment. If a skin
reaction develops, discontinue using the device and consult your physician. Do not treat the patch tested
area for at least one week after the test.

Treatment methods

The area to be treated must be hair-free, clean and dry. Before pushing the treatment button, look away
from the device to avoid the bright light.
GLIDING
for fast and efficient
treatment of large areas
(e.g. legs).
1. Place the treatment window firmly on your skin, ensuring both skin sensors have skin contact.
The power bars (3) show white LEDs
light skin tone U high light intensity
dark skin tone U low light intensity
no LEDs
no skin contact U device will not flash
red LED
invalid skin tone U device will not flash
STAMPING
for treating small,
hard-to reach areas
(e.g. face for females,
bikini line, underarms,
knee, chin, ankles)