Performing a functional test

MWE890
NOTE
I
If the speedometer speed signal has been disconnected from the
control electronics, the default settings must be restored to ensure
that the sensors function correctly.
➤ Switch on the ignition.
➤ Press the button for longer than two seconds.
✓ The loudspeaker beeps repeatedly.
➤ Let go of the button.
✓ The system has been reset to the default settings.
8.4
Reflecting the display (MWE860 only)
If the obstacles are shown the wrong way round on the display, proceed as
follows:
➤ Connect the sensor plugs into the sockets on the control module in the re-
verse order (1 → 4, 2 → 3, 3 → 2, 4 → 1).
9
Performing a functional test
To test the parking aid, drive towards something slowly such as a wall.
NOTICE!
A
Be very careful when you operate the device for the first time, and
make sure that you familiarize yourself with the various sequences
of beeps (fig. d).
24