Protection Circuit Specification - Pioneer VSX-2016AV-S Service Manual

Audio/video multi-channel receiver
Hide thumbs Also See for VSX-2016AV-S:
Table of Contents

Advertisement

1

7.1.2 PROTECTION CIRCUIT SPECIFICATION

QQ
3 7 63 1515 0
A
Protection Circuit Process List
Item
Purpose
To detect amplifier damage
(defect status)
A process to protect speakers
DC
(for protection of connected
detection
external devices)
To detect overloading
(abnormal status)
AMP
With low-load driving or a
overload
B
short circuit of the speaker
terminals (for protection of the
amplifier)
Self reset type protection
Overheat
feature by temperature-rise of
detection
heat sink
12V
To detect the shortcircuit of
trigger
12V trigger output (load more
failure
than 50mA) (for protection of
detection
the amplifier)
C
TE
L 13942296513
DC Detection Circuit
AG
POWER AMP-R ASSY
+VL
D
IC5301
R5341
OUTPUT
R ch
R5342
IC5302
E
SR ch
-VL
SBR ch
+DC detection: Q5571 base is "H".
→ Collector of Q5571 and Q5572 are "L".
-DC detection: Q5572 emitter is minus to the base.
→ Collector of Q5571 and Q5572 are "L".
www
F
198
1
http://www.xiaoyu163.com
2
Detection Method
Detects when the DC_PROTECT
port becomes "L".
(Pin 120 of IC101)
Detects when the OL_DET port
becomes "L" (checks by interrupt).
(Pin 28 of IC101)
Detects when the TEMP2 port
becomes "H" .
(Pin 44 of IC2301)
Detects when the 12VDET port
decoms "H".
(Pin 44 of IC2301)
DC DETECTOR
CN5302
CN5702
-5
Q5571
Q5572
GAMP
R5441
R5442
CN5301
CN5602
-6
-8
R5541
R5542
x
ao
POWER
y
AMP IN ASSY
.
i
VSX-2016AV-S
2
http://www.xiaoyu163.com
3
8
Process
Warning Indication
Turns muting on and
speaker relay off, then
Flashing "AMP ERR" for
turns off the power after 3
3 seconds.
seconds. Then flashes
MCACC indicator.
Turns muting on and
speaker relay off, and
immediately turns off the
None
power. Then flashes
PHASE CONTROL
indicator.
Turns muting on and
speaker relay off, then
Flashing "OVERHEAT"
turns off the power after 3
for 3 seconds.
seconds.
Turns 12V trigger output
Flashing "12V ERR"
to off.
Q Q
3
6 7
AJ
POWER
PROTECT
C
ASSY
V+5UM
R5721
CN5703
CN103
-7
-15
-5
FFC J43
R5714
GNDU
CN5601
CN5001
-8
-6
C ch
L ch
SL ch
AI
AD
POWER AMP-L ASSY
u163
3
4
2 9
9 4
Remarks
Once detected and turned
the power off, input a key
never again. If the
DC_DET port becomes
"H" within 3 seconds, the
unit returns to normal
condition automatically.
If the TEMP2 port
becomes "L" within 3
seconds, the unit returns
to normal condition
automatically.
Continue showing
warning.
Release the FL indication
by switching the INPUT
SEL or the turns the power
off.
1 3
1 5
0 5
8
2 9
MAIN CONTROL ASSY
UCOM
Normal: High (5V)
DC det: Low (0V)
IC101
120
SBL ch
m
co
.
4
2 8
9 9
9 4
2 8
9 9

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vsx-81txv-sVsx-81txvVsx-9110txv-k