GUTMANN INVISIBLE Installation Instructions Manual page 19

Hide thumbs Also See for INVISIBLE:
Table of Contents

Advertisement

6. Connect the connection piece of
the extraction unit to the exhaust air
duct and seal it.
7. Now fix the extraction unit to the
ceiling / wall of the cabinet; make
sure that the gaps around it are
even.
8. Install the controller in the base
(close to the glass panel). Ensure
that it is accessible in the event of
maintenance work.
9. Install the motor cable between
the fan unit and the controller.
10. Create the recess for the glass
panel in the work top; ensure that
Fill the gap with silicone
the distance between the controller
and the glass panel is less than 2
m. Install the control cable between
the glass panel and the controller
(drawing of glass panel, see page
25).
11. Use silicone to fix the glass
panel in place; make sure that the
gaps around it are even.
12. Carry out a functional test!