Installation; Prior To The Installation; Wall Mounting; Storage Tank Mounting - Wagner & Co RATIOfresh 250 Technical Information Installation Instructions

Freshwater station
Table of Contents

Advertisement

3. Installation

3.1 Prior to the Installation

Before assembly, please compare the delivered compo-
nents with the parts list in table 3.
You need the following tools: drill, stone drill (12 mm),
voltage meter, screwdriver, folding meter-rule, wrench
size 10, monkey wrench, ratchet with size 13 socket.
Materials/components needed on-site: sets of union
connectors to connect primary and potable water cir-
cuit, a safety subassembly to install into potable water
network if needed, a circulation pump if needed, pipe
material, and insulation material.
Open the RATIOfresh freshwater station as depicted in
fig. 8 by removing the housing cover in the lower section
from the lower part and lift out off the snap-in groove.
3.2 Wall Mounting (fig. 4)
Transfer the hole pattern to the wall as depicted in fig. 4.
Drill holes (1) with a 12-mm stone drill and insert in-
cluded plugs (2).
Insert screws (3) to a distance of 1 cm and insert housing
(4) into keyholes (5) and attach screws.
Tighten screws (3) firmly.
3.3 Storage Tank Mounting (fig. 5)
The RATIOfresh freshwater station is suitable for mounting
directly on all buffer cylinders (RATIO-H series) using the
additionally available tank expansion kit (cf. accessories,
table 4):
Remove the insulation of the RATIO-H (1) cylinder and
snap the mounting plate (3) with the U-shaped ends (4)
into the second (2) and fifth connection (5) from the top.
Screw down the mounting plate with the included 1 1/2"
flat swivel nuts (6).
Then screw the included 3 hexagonal carriage bolts (7)
halfway into the mounting plate, attach lower part of
housing with keyhole drill holes (fig. 4) and tighten with
the carriage bolts (7).
Figure 5 Tank mounting
1 RATIO-H cylinder; 2 Second connection from top;
3 Mounting plate; 4 Bracket; 5 Fifth connection from top;
6 1¼" flat swivel nut; 7 Hexagonal carriage bolts.
8
254
1
827
Figure 4 Wall mounting
1 Holes; 2 Plugs; 3 Screws; 4 Bottom section of housing;
5 Keyholes.
1
2
5
EN-RATIOfresh-250-400_TI-MA-0809-11214900
4
2
4
3
5
5
5
4
6
3
4
6
3
7

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ratiofresh 400

Table of Contents