1-3. Electrical Alignment
Checking After the Adjustments
1
Setting for the TEST2 mode
(1) Press the CONFIGURATION button of the menu operation block of the MSU-700. (The CONFIGU-
RATION button will light.)
The Configuration Menu appears on the display.
(2) Press [Camera] of the Configuration Menu.
The CAM Configuration display appears.
(3) Press [10|Step] in the Test2 Mode section.
The output signal will be changed to a ten-step waveform.
(4) Press the TEST2 button on the MSU-700 control panel.
2
Checking the CAMERA TEST OUT signal
(1) Connect the waveform monitor to the TEST OUT connector on the camera.
(2) Make sure that the output signal meets the specification.
A = 100 ± 1.5 IRE (NTSC)
Specification:
A = 700 ± 10 mV (PAL)
A
(3) If the specification is not met, readjust all the adjustments shown in step (2) in the above "Adjust-
ment" section.
3
Checking the CCU VBS OUT signal
(1) Connect the waveform monitor to the VBS OUT connector (one of connectors VBS 1 to VBS3) on
the CCU.
(2) Make sure that the output signal meets the specification.
B = 100 ± 2 IRE (NTSC)
Specification:
B = 700 ± 10 mV (PAL)
B
(3) If the specification is not met, readjust all the adjustments shown in step (2) in the above "Adjust-
ment" section.
4
Resetting After the Completion
Return the output signal to a three-step waveform in the TEST2 mode.
(1) Press [3|Step] in the Test2 Mode section.
(2) Press the CONFIGURATION button to go off.
1-10 (E)