7.1
Wiring diagram for PEX 3000
PEX 3000
Type XTR 0000,
XTR 0001,
XTR 0010
and XTR 0011
PEX 3000, all types
Connection to central controller:
Connect terminal +24 V to +24 volts
Connect terminal SIG to 4 bis 20 mA input
Connect terminal 0 V to 0 volts
Dräger SAM 3100/3200
Cable screen
contacted within
the cable gland
Type XTR 0090,
Cable screen
contacted within
the cable gland
1 2 3
1 2 3
PEX 3000
XTR 0091
max. cable length
Sensing head
Polytron SE Ex PR ... DD
PEX 3000, types XTR 0090 and XTR 0091
Connection to sampling head
Connect terminal br/br to terminal 1
Connect terminal ge/yw to terminal 2
Connect terminal sw/bk to terminal 3
Power supply
+24 Volts
24 V 20 %,
0 Volt
4 to 20 mA
0 mA
Controller Unit
core cross-section
50 m
0.5 mm
100 m
1.0 mm
150 m
1.5 mm