Dräger SAM 3100 / 3200
Sampling system
Instructions for Use
i

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SAM 3100 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Dräger SAM 3100

  • Page 1 Dräger SAM 3100 / 3200 Sampling system Instructions for Use...
  • Page 3: Table Of Contents

    Wiring diagram for PIR 7000 / PIR 7200 ..11 List of materials ......12 Dräger SAM 3100/3200...
  • Page 4: For Your Safety

    (SAM 3100) or for two gas transmitters (SAM 3200), in order  Do not use a faulty or incomplete product. Do not modify to carry out measurements of toxic and/or explosive the product.
  • Page 5: Specification

    Specification Settings Example arrangements Dräger SAM 3100 without Dräger SAM 3200 with gas gas sampling pump: sampling pump: Air quantity The flow should be set according to the sensor type:  Transmitter with electrochemical sensor ~60 l/h Transmitter with electrochemical sensor + IR transmitter ...
  • Page 6: Motor Circuit Protector (Option)

    Slide the lock nut and clamping ring over the hose as illustrated. Mechanical fastening  The Dräger SAM 3100 / 3200 aspirator system is delivered fully assembled.  The installation of the base plate or housing depends on the local situation. Ensure that the installation is sufficiently firm and free of vibration.
  • Page 7: Electrical Connections

    The electrical connection of the installed, intrinsically safe, equipment to the + and – terminals is carried out in accordance with the following illustration and table. A limit sensor is connected to each terminal block. Pay attention to the specified polarity. Dräger SAM 3100/3200...
  • Page 8: Maintenance

    Maintenance Maintenance Dräger SAM 3100/3200 aspirator system: The aspirator system is designed so as to minimise the need for servicing.  Directions for maintenance and servicing can be found in the Instructions for Use for the components used.  Depending on the dust load in the sample gas, the filter inserts should be replaced when visibly soiled.
  • Page 9: Wiring Diagram For Pex 3000

    Connect terminal +24 V to +24 volts Connect terminal br/br to terminal 1 Connect terminal SIG to 4 bis 20 mA input Connect terminal ge/yw to terminal 2 Connect terminal 0 V to 0 volts Connect terminal sw/bk to terminal 3 Dräger SAM 3100/3200...
  • Page 10: Wiring Diagram For Polytron 3000 / Polytron 7000

    Explosion-hazard area, zone 2 or non-explosion hazard Non-explosion-hazard area without a safety barrier 4 ... 20 mA – Control unit +24 V 4 to 20 mA 02323944_en.eps Dräger SAM 3100/3200...
  • Page 11: Wiring Diagram For Polytron 3000 / Polytron 7000

    1 2 3 4 5 6 power supply – central device, e.g. Dräger REGARD 2123944_en.eps Wiring diagram for operation as a 4 to 20 mA current sink (sink operation): – 1 2 3 4 5 6 power supply – central device 02223944_en.eps Dräger SAM 3100/3200...
  • Page 12: List Of Materials

    List of materials Name Order no. Manufacturer Gas transmitter and sensor type According to customer requirements Dräger Aspirator system SAM 3100 / 3200 – Dräger for a gas transmitter, comprising:  Base plate, 500 mm x 500 mm, stainless steel –...
  • Page 16 Dräger Safety AG & Co. KGaA Revalstraße 1 23560 Lübeck, Germany Tel +49 451 882 0 Fax +49 451 882 20 80 www.draeger.com 90 23 944 - GA 4675.790 de © Dräger Safety AG & Co. KGaA Edition 02 - September 2013 (Edition 01 - October 2006) Subject to alteration...