Maintenance Contract - Trane CONQUEST CGAX 015 Installation Operation & Maintenance

Air-cooled scroll chillers and heat pumps 43-164 kw
Table of Contents

Advertisement

General Information

Maintenance contract

It is strongly recommended that you sign a maintenance
contract with your local Service Agency. This contract
provides regular maintenance of your installation by a
FWD
specialist in our equipment.
Power supply
Capacities
Regular maintenance ensures that any malfunction is
Cooling capacity on water (1)
detected and corrected in good time and minimizes
Heating capacity on water (2)
the possibility that serious damage will occur. Finally,
Fan motor
regular maintenance ensures the maximum operating
Fan power input (3)
Current amps (3)
life of your equipment.
Start-up amps
We would remind you that failure to respect these
Air flow
minimum
installation and maintenance instructions may result in
nominal
immediate cancellation of the warranty.
maximum
Main coil
Training
Water entering/leaving connections
Electric heater (accessory for blower only)
To assist you in obtaining the best use of it and
Electric power supply
maintaining it in perfect operating condition over a long
Heating capacity
period of time, the manufacturer has at your disposal a
Hot water coil (accessory for blower only)
Heating capacity (4)
refrigeration and air conditioning service school.
G2 filter (filter box accessory)
The principal aim of this is to give operators and
Quantity
Dimensions ( LxWxth)
technicians a better knowledge of the equipment they
G4 filter (filter box accessory)
are using, or that is under their charge. Emphasis is
Quantity
particularly given to the importance of periodic checks on
Dimensions ( LxWxth)
the unit operating parameters as well as on preventive
Condensate pump (accessory)
Water flow - lift height
maintenance, which reduces the cost of owning the unit
Not available for FWD30 and FWD45
by avoiding serious and costly breakdown.
Sound level (L/M/H speed)
Sound pressure level (5)
Sound power level (5)
Unit dimensions
Width x Depth
Height
Shipped unit dimensions
Width x Depth
Height
Weight
Colour
Recommended fuse size
Unit alone (aM/gI)
Unit with electric heater (gI)
(1) Conditions: Water entering/leaving temperature: 7/12 °C, Air inlet temperature 27/19°C DB/WB - Nominal air flow
(2) Conditions: Water entering/leaving temperature: 50/45 °C, Air inlet temperature 20°C DB - Nominal air flow
(3) At high speed with nominal air flow.
(4) Water entering/leaving temperature 90/70 °C, air inlet temperature 20 °C DB, Nominal air flow.
(5) A rectangular glass wool duct 1m50 long is placed on the blower.The measurement is taken in the room containing the blower unit.
Heat exchanger operating limits:
FWD:
*water temperature: max 100° C
*absolute service pressure: min 1 bar/max 11 bars
Accessories - Hot water coil:
*water temperature: min. +2° C/max. 100° C
*absolute service pressure: min 1 bar/max 11 bars
4 4
Technical Data
08
(V/Ph/Hz)
(kW)
5,2
(kW)
6,3
(type)
(kW)
0,23
(A)
1,1
(A)
3,2
(m
/h)
490
3
(m
/h)
820
3
(m
/h)
980
3
(type)
(Dia)
3/4"
(V/Ph/Hz)
230/1/50
(kW)
2/4
(kW)
6,3
2
(mm)
386x221x8
-
(mm)
-
(type)
(l/h - mm)
(dB(A))
36/40/43
(dB(A))
46/50/53
(mm)
890 x 600
(mm)
250
(mm)
933 x 644
(mm)
260
(kg)
32
(A)
8/16
(A)
16 (2kW),25 (4kW)
12
20
230/1/50
8,3
15
11,9
18,9
2 x direct drive centrifugal
0,46
0,65
2,2
3,1
5,5
9,3
980
1400
1650
2300
1970
2600
ISO R7 rotating female
3/4"
1 1/2"
230/1/50 or 400/3/50
400/3/50
8
10
12
17,4
2
2
486x271x8
586x321x8
2
2
486x264x48
586x314x48
Centrifugal
24 - 500
38/41/44
46/50/53
48/51/54
56/60/63
1090 x 710
1290 x 820
300
350
1133 x 754
1333 x 864
310
360
46
61
galvanised steel
8/16
8/16
40 (230V),3*16 (400V)
3*20
30
45
18,8
30,1
20,9
38,2
1,04
1,51
4,7
5,5
14,1
16,5
1800
2700
3000
4500
3600
5400
1 1/2"
1 1/2"
400/3/50
400/3/50
12
12
22,4
34,5
2
2
586*421*8
586*621*8
2
2
586*414*48
586*614*48
47/52/57
47/52/58
57/62/67
57/62/68
1290 x 970
1290 x 1090
450
650
1333 x 1008
1333*1133
460
660
76
118
8/25
8/25
3*25
3*25
UNT-PRC002-GB
CG-SVX027D-GB

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents