Installing replacement consumables
Replacing the key card:
1. Make sure the power supply is disconnected. The key card can be
removed by gently pressing down on the small tab on the top of the
card whilst pulling it out of the card slot.
2. When inserting the new card the label side of the key card should face
the front and it should be inserted in the direction of the arrow on the
card. This will activate the machine for 1000 more disc cleans.
Removing and replacing the cleaning roller and cleaning bottle:
1. Remove the clear plastic safety cover by pushing it outwards and
pulling down as illustrated.
2. Remove the roller retaining disc by holding the roller and rotating the
disc 90 degrees.
3. Remove the used roller from the shaft.
4. Slide the new roller onto the shaft making sure that it is all the way on.
5. Replace the roller retaining disc by holding the roller and rotating the
disc 90 degrees.
6. Replace the clear plastic safety cover by inserting the top first and
pushing into place.
7. Replacing the cleaning bottle and prime as described in the installation
section.
8. Reconnect the power supply and your EcoClean is ready for a further
1000 cleans.
©Total Disc Repair
|
www.totaldiscrepair.co.uk
|
Technical Support: 0800 412 5424 - support@totaldiscrepair.co.uk
Operating hints and care advice
After several cycles, some fluid may accumulate in the machine. If this
happens, wipe the disc cleaning camber with a dry and soft cloth.
Some residue may appear on hard coated discs after cleaning. With such
discs simply hold the cover down for a few seconds longer after the led
turns to orange to remove the residue by dry buffing.
Dust or dirt could contaminate the cleaning roller which may cause light
scratches. If the Cleaning Roller is dirty, it should be washed or replaced.
When necessary, remove the Cleaning Roller from the machine and clean
it in a mild detergent. Be sure that it is completely dry before using the
Roller again.
Disconnect the power supply before inserting or removing the key card
Failure to do this will cause the key card to fail.
If the machine has not been used for some time confirm that Cleaning
Fluid flows out from the spray nozzle by closing and opening the cover
with the power supply disconnected.
Do not close the Cover with the power connected unless you are cleaning
a disc. Damage could be caused to the cleaning roller and the number of
disc cleans in the programmed key card would be reduced.
When you have finished cleaning discs for the day, we recommend that
you disconnect the power supply from the wall outlet.
If your EcoClean becomes dirty, clean it using a mild detergent and dry
it with a soft cloth. Do not use strong cleaners or solvents which could
damage the finish of the machine.
If the EcoClean sits idle for a long period of time, the cleaning fluid in
the tubes can evaporate. In this case, you will need to prime the fluid
lines and the pump again.
|