MAINTENANCE
Since the DIAMANT is operated with mains water, regular decalcification is required to
assure the useful life of the device as ensure proper functioning. The frequency of decalci
fication will depend on water hardness and duration of utilisation.
For average water hardness (10
mend that the device be decalcified at least every three months.
Please proceed as follows:
• Fill the tank half full (approximately I litre of water) and add a commercially available
decalcifier in the appropriate quantity.
• Screw the filler cap tight
• Turn on the main switch and steam supply line switch
• Wait until the diode lights up
• Turn the main switch off again and fully release the steam pressure to the spray gun
using the steam button
• Allow the device to cool for a few minutes
• Empty the device and rinse the tank twice with clear water
• When using cleansing vinegar, allow the device to stand for a few hours or over night
before emptying it, and then rinse it thoroughly several times
Important: The drain screw to empty the tank is located on the bottom of the device.
Do not open before releasing all steam.
After emptying the tank, retighten the screw.
TECHNICAL DATA
Input
Boiler output
Boiler capacity
Steam temperature
Maximum pressure
Profi electric iron
Boiler
°
°
-15
) and normal use in a private household, we recom
120V-60Hz
1500W
21
°
150
c / 315°F
500 kPa (5 bar)
850W
Stainless
12
Need help?