Miele SmartLine CSDA 7000 Operating And Installation Instructions

Downdraft extractor

Advertisement

Quick Links

Operating and installation instructions
SmartLine downdraft extractor
To avoid the risk of accidents or damage to the appliance it is essential
to read these instructions before it is installed and used for the first time.
en-GB
M.-Nr. 10 746 530

Advertisement

Table of Contents
loading

Summary of Contents for Miele SmartLine CSDA 7000

  • Page 1 Operating and installation instructions SmartLine downdraft extractor To avoid the risk of accidents or damage to the appliance it is essential to read these instructions before it is installed and used for the first time. en-GB M.-Nr. 10 746 530...
  • Page 2: Table Of Contents

    Contents Warning and Safety instructions................ 4 Caring for the environment ................ 14 Guide to the appliance .................. 15 Downdraft extractor....................15 Controls / Indicators....................16 Accessories supplied .................... 17 Cleaning the SmartLine element for the first time ...........  18 Modes of operation .....................  19 Tips on saving energy ..................
  • Page 3 Contents Installation – surface-mounted................43 Flush-fit ......................... 48 Installation notes – flush-fit ................... 48 Worktop cutout – flush-fit..................50 Spacer bars – flush-fit ................... 53 Installation dimensions – Flush ................54 Air duct dimensions – flush-fit – worktop depth 600 mm ........55 Air duct dimensions –...
  • Page 4: Warning And Safety Instructions

    Miele cannot be held liable for injury or damage caused by non- compliance with these instructions. Keep these instructions in a safe place and pass them on to any future owner.
  • Page 5 Warning and Safety instructions Correct application  This downdraft extractor is intended for use in domestic house- holds and similar working and residential environments.  The downdraft extractor is not suitable for outdoor use.  It must only be used as a domestic appliance to extract vapours and remove odours from cooking.
  • Page 6 Warning and Safety instructions Safety with children  Children under 8 years of age must be kept away from the coun- tertop extractor unless they are constantly supervised.  Children aged 8 and older may only use the countertop extractor without supervision if they have been shown how to use it in a safe manner.
  • Page 7: Technical Safety

     Unauthorised installation, maintenance and repairs can cause considerable danger for the user. Installation, maintenance and re- pairs must only be carried out by a Miele authorised technician.  The downdraft extractor must only be installed and operated in combination with those SmartLine elements and hob units specified by Miele.
  • Page 8 The manufacturer's warranty will be invalidated if the downdraft extractor is not repaired by a Miele approved service technician.  Miele can only guarantee the safety of the appliance when genu- ine original Miele replacement parts are used. Faulty components must only be replaced by Miele spare parts.
  • Page 9 Warning and Safety instructions  During installation, maintenance and repair work, the downdraft extractor must be completely disconnected from the mains electri- city supply. It is only completely isolated from the electricity supply when: – the mains fuse has been disconnected or –...
  • Page 10 Warning and Safety instructions Using at the same time as other heating appliances that depend on the air from the room  Danger of toxic fumes! Great care should be taken when using the downdraft extractor in the same room or the same area of the house as another heating appliance that depends on the air from the room.
  • Page 11 Warning and Safety instructions In order to ensure safe operation and to prevent gases given off by the heating appliance from being drawn back into the room, when the downdraft extractor and the heater are both operated simultan- eously, an underpressure in the room of 0.04 mbar (4 Pa) is the maximum permissible.
  • Page 12: Correct Use

    Warning and Safety instructions Correct use  Open flames are a fire hazard. Never use an open flame beside the downdraft extractor. To avoid the danger of fire, do not flambé or grill over an open flame. When switched on, the downdraft extractor could draw flames into the fil- ter.
  • Page 13 There is a risk of fire if the cooker hood is not cleaned as de- scribed in these operating instructions. Accessories  Only use genuine original Miele accessories and spare parts with this appliance. Using accessories or spare parts from other manu- facturers will invalidate the warranty and Miele cannot accept liabil- ity.
  • Page 14: Caring For The Environment

    / recycling centre for electrical and electronic ap- pliances, or contact your dealer or Miele for advice. You are also respons- ible for deleting any personal data that may be stored on the appliance being disposed of. Please ensure that your old appliance poses no risk to children while being stored prior to disposal.
  • Page 15: Guide To The Appliance

    Guide to the appliance Downdraft extractor a FlameGuard b Grease filter c Cover with control unit d Casing e Grease trap f Air duct g Fan h E-box...
  • Page 16: Controls / Indicators

    Guide to the appliance Controls / Indicators a Switching the downdraft extractor on/off b Numerical keybank for setting the power level...
  • Page 17: Accessories Supplied

    Guide to the appliance Accessories supplied The accessories supplied with your ap- pliance as well as a range of optional ones are available to order from Miele (see “Optional accessories”). FlameGuard For installing between the downdraft extractor and a gas cooking element...
  • Page 18: Cleaning The Smartline Element For The First Time

    Cleaning the SmartLine element for the first time  Please stick the extra data plate for the appliance supplied with this doc- umentation in the space provided in the “After sales service” section of this booklet.  Remove any protective wrapping and stickers.
  • Page 19: Modes Of Operation

    Modes of operation Depending on the model of the downdraft extractor, the following op- tions are available: Extraction mode The air is drawn in and cleaned by the grease filter and directed outside. Recirculation mode (DUU 1000(-1) conversion kit required) The air is drawn in and cleaned by the grease filter.
  • Page 20: Tips On Saving Energy

    Tips on saving energy This downdraft extractor operates very efficiently and economically. The follow- ing will help you to save even more en- ergy when using it: – It is important to ensure that the kit- chen is well ventilated during opera- tion.
  • Page 21: Operation

    Operation FlameGuard Setting/changing the power level For light to heavy cooking vapours and odours, select from power levels 1 to 3. For short periods of cooking food with intensive vapours and a strong aroma, e.g. when searing meat, select Booster setting  B.
  • Page 22: Run-On Time

    Operation Run-on time In order to rid kitchen air of steam and odours, the downdraft extractor contin- ues to run for 5 minutes on the power level that was set last. The power level is gradually reduced during the run-on time. The current power level pulsates during the run-on time.
  • Page 23: Cleaning And Care

    Cleaning and care  Allow the SmartLine element to cool Danger of burning due to hot down before cleaning. surfaces. The surfaces will be hot after cook-  Clean the SmartLine element and ac- ing. cessories after each use. Switch the countertop extractor and ...
  • Page 24: Ceramic Surface

     Clean and dry the accessible inside  Then clean the ceramic glass surface of the downdraft extractor. with the Miele ceramic and stainless  Fasten the drip tray back onto the steel hob cleaner (see “optional ac- cessories”) or with a proprietary casing.
  • Page 25: Grease Filter

    Cleaning and care  Use a commercially available house- Grease filter hold dishwasher detergent. The reusable metal grease filter in the  Select a dishwasher programme with vapour extraction fan removes solid a wash temperature between 50 °C particles from kitchen vapours (grease, and 65 °C.
  • Page 26: Problem Solving Guide

    There is no power to the SmartLine element. cannot be switched on.  Check whether the mains fuse has tripped. Con- tact an electrician or Miele Service (for the min- imum fuse rating, see data plate). There may be a technical fault.
  • Page 27: Optional Accessories

    Miele appliances. These products can be ordered through the Miele Webshop. They can also be ordered from Miele (see end of this booklet for contact de- tails) or from your Miele dealer. For installing between the downdraft...
  • Page 28: After Sales Service

    In the event of any faults which you cannot remedy yourself, please contact your Miele Dealer or Miele Service. Contact information for Miele Service can be found at the end of this document. Please note that telephone calls may be monitored and recorded for training pur- poses and that a call-out charge will be applied to service visits where the problem could have been resolved as described in this booklet.
  • Page 29: Installation

    (e.g. a drawer) or be subject to mechanical loads which could damage it.  Combination with gas appliances Only Miele CS 7xxx gas appliances may be installed next to the downdraft extractor.  Observe carefully the safety clearances listed on the following pages.
  • Page 30: Installation Examples

    Installation Installation examples Recirculation mode Extraction mode...
  • Page 31: Surface-Mounted

    Installation Tiled worktop Surface-mounted Installation notes – surface-mounted Sealing between the SmartLine Ele- ment and the worktop Grout lines  and the hatched area un- derneath the SmartLine element frame must be smooth and even. If they are not, the SmartLine element will not sit flush with the worktop and the sealing strip underneath the top part of the ap- pliance will not provide a good seal...
  • Page 32 Installation Installing several Worktop depth SmartLine elements The downdraft extractor can be in- The gaps between the individual Smart- stalled with the connector for the air Line elements are sealed with a silicone duct on either the right or the left-hand sealant that is heat-resistant to at least side.
  • Page 33: Worktop Cutout - Surface-Mounted

    Installation Worktop cutout – surface-mounted Information for calculating the cutout The elements overlap the worktop by 10 mm. When installing several elements, a distance of 2 mm must be observed between the individual elements. Calculating cutout dimension B 1 element = Width of the element minus 10 mm on the right, minus 10 mm on the left Several elements = Total width of the elements plus 2 mm distance between the elements, minus 10 mm on the right, minus 10 mm on the left.
  • Page 34 Installation Installation with a downdraft extractor Combination examples Number x width [mm] Dimen- sion B Cooking ele- Downdraft ex- [mm] ments tractor 1 x 378 1 x 120 2 x 378 1 x 120 1 x 378 2 x 120 1224 1 x 620 3 x 378 2 x 120 1362 2 x 378 2 x 120 1604 1 x 620 4 x 378 2 x 120 1742 1 x 620 2 x 120...
  • Page 35 Installation Installation without a downdraft extractor Combination examples Number x width [mm] Dimension B [mm] Cooking elements 1 x 378 2 x 378 1 x 378 1 x 620 3 x 378 1118 2 x 378 1360 1 x 620 4 x 378 1498...
  • Page 36: Spacer Bars - Surface-Mounted

    Installation Spacer bars – surface-mounted When installing several SmartLine elements, an additional spacer bar must be fit- ted in between the individual elements. The clips supplied with the spacer bars are only required for installing a CSDA 700x FL. Installing 3 elements and 2 spacer bars Spacer bars for the downdraft extractor –...
  • Page 37: Installation Dimensions - Surface-Mounted

    Installation Installation dimensions – Surface-mounted All dimensions are given in mm. a Front b Fan (in the plinth on the floor) c Air duct d E-box...
  • Page 38: Air Duct Dimensions - Surface-Mounted - Worktop Depth 600 Mm

    Installation Air duct dimensions – surface-mounted – worktop depth 600 mm Side view a For maintenance work it must be possible to remove the rear cabinet wall. The cabinet wall and an adjoining room wall or a piece of furniture must be at least 110 mm apart to ensure sufficient room for the ducting.
  • Page 39 Installation Front view View from above...
  • Page 40: Air Duct Dimensions - Surface-Mounted - Worktop Depth Greater Than 600 Mm

    Installation Air duct dimensions – surface-mounted – worktop depth greater than 600 mm View from the side – right air duct connection a For maintenance work it must be possible to remove the rear cabinet wall. The cabinet wall and an adjoining room wall or a piece of furniture must be at least 110 mm apart to ensure sufficient room for the ducting.
  • Page 41 Installation View from the front – right air duct connection View from above – right air duct connection...
  • Page 42 Installation If you want to install the air duct to the left of the downdraft extractor, the work- top must be at least 665 mm deep. View from the front – left air duct connection View from above – left air duct connection...
  • Page 43: Installation - Surface-Mounted

    Installation Wooden worktops Installation – surface-mounted If the worktop is more than 24 mm deep, it must be cut out underneath on the building-in side on the right or left hand side.  Fit the bracket so that it sits flush with the top edge of the worktop cutout.
  • Page 44 Installation Preparing the worktop Wooden worktops  Create the worktop cutout. Remem- ber to maintain the minimum safety distances (see “Installation – Safety distances”).  Seal any cut surfaces on wooden worktops with a special varnish, sil- icone sealant or resin to prevent the wood from swelling as a result of moisture ingress.
  • Page 45 Installation Installing the downdraft extractor The downdraft extractor can be in- stalled with the connector for the air duct on either the right or the left-hand side.  Remove the grease trap from the cas- ing. a Connector for air duct on the right ...
  • Page 46 Installation E-box Connection to window contact, if re- quired  The window contact connection is live! Danger of electric shock! Disconnect the countertop extractor from the mains before connecting the switching system. The connection cable of the switch- ing system must only be connected a Mains connection cable by a suitably qualified and compet- b Connection to window contact...
  • Page 47 Installation  Loosen the lug and pull the plug out. Connecting the e-box  Connect the operating voltage and fan control cables to the e-box and the fan.  Connect the control unit cable to the e-box. The socket positions are designed in such a way that they cannot be mixed ...
  • Page 48: Flush-Fit

    Installation Natural stone worktops Flush-fit The SmartLine element is set directly in Installation notes – the cutout. flush-fit Solid wood worktops, tiled worktops, glass worktops Flush-fit installation is only possible in natural stone (granite, marble), solid The SmartLine element is set on a wood and tiled worktops.
  • Page 49 Installation Installing several Worktop depth SmartLine elements The downdraft extractor can be in- The gaps between the individual Smart- stalled with the connector for the air Line elements are sealed with a silicone duct on either the right or the left-hand sealant that is heat-resistant to at least side.
  • Page 50: Worktop Cutout - Flush-Fit

    Installation Worktop cutout – flush-fit Natural stone worktop Wooden worktop + 0.5  mm with CS 7611 FL Information for calculating the cutout The elements overlap the worktop by 10 mm. When installing several elements, a distance of 2 mm must be observed between the individual elements. Calculating cutout dimension A 1 element = Width of the element plus 2 mm on the right, plus 2 mm on the left.
  • Page 51 Installation Installation with a downdraft extractor Combination examples Number x width [mm] Dimen- Dimen- sion A sion B Cooking ele- Downdraft [mm] [mm] ments extractor 1 x 378 1 x 120 2 x 378 1 x 120 1 x 378 2 x 120 1248 1224 1 x 620 3 x 378 2 x 120 1386 1362 2 x 378 2 x 120 1628 1604 1 x 620 4 x 378 2 x 120 1766 1742...
  • Page 52 Installation Installation without a downdraft extractor Combination ex- Number x width Dimension A Dimension B amples [mm] [mm] [mm] Cooking elements 1 x 378 2 x 378 1 x 378 1004 1 x 620 3 x 378 1142 1118 2 x 378 1384 1360 1 x 620 4 x 378 1522 1498...
  • Page 53: Spacer Bars - Flush-Fit

    Installation Spacer bars – flush-fit When installing several SmartLine elements, an additional spacer bar must be fit- ted in between the individual elements. The clips supplied with the spacer bars are only required for installing a CSDA 700x FL. Installing 3 elements and 2 spacer bars Spacer bars for the downdraft extractor –...
  • Page 54: Installation Dimensions - Flush

    Installation Installation dimensions – Flush All dimensions are given in mm. a Front d 12 mm wooden frame (not supplied, for detailed illustrations, see “Installa- b Fan (in the plinth on the floor) tion – Worktop cutout – flush-fit”) c Stepped cutout (for detailed illustra- e Air duct tions, see “Installation –...
  • Page 55: Air Duct Dimensions - Flush-Fit - Worktop Depth 600 Mm

    Installation Air duct dimensions – flush-fit – worktop depth 600 mm Side view a For maintenance work it must be possible to remove the rear cabinet wall. The cabinet wall and an adjoining room wall or a piece of furniture must be at least 110 mm apart to ensure sufficient room for the ducting.
  • Page 56 Installation Front view View from above...
  • Page 57: Air Duct Dimensions - Flush-Fit - Worktop Depth Greater Than 600 Mm

    Installation Air duct dimensions – flush-fit – worktop depth greater than 600 mm View from the side – right air duct connection a For maintenance work it must be possible to remove the rear cabinet wall. The cabinet wall and an adjoining room wall or a piece of furniture must be at least 110 mm apart to ensure sufficient room for the ducting.
  • Page 58 Installation View from the front – right air duct connection View from above – right air duct connection...
  • Page 59 Installation If you want to install the air duct to the left of the downdraft extractor, the work- top must be at least 665 mm deep. View from the front – left air duct connection View from above – left air duct connection...
  • Page 60: Installation - Flush-Fit

    Installation Wooden worktops Installation – flush-fit If the worktop is more than 28 mm deep, it must be cut out underneath on the building-in side on the right or left hand side.  Fit the bracket so that it sits flush with the top edge of the lower step of the stepped cutout.
  • Page 61 Installation Preparing the worktop Wooden worktops  Create the worktop cutout. Remem- ber to maintain the minimum safety distances (see “Installation – Safety distances”).  Seal any cut surfaces on wooden worktops with a special varnish, sil- icone sealant or resin to prevent the wood from swelling as a result of moisture ingress.
  • Page 62 Installation Installing the downdraft extractor The downdraft extractor can be in- stalled with the connector for the air duct on either the right or the left-hand side.  Remove the grease trap from the cas- ing. a Connector for air duct on the right ...
  • Page 63 Installation E-box Connection to window contact, if re- quired  The window contact connection is live! Danger of electric shock! Disconnect the countertop extractor from the mains before connecting the switching system. The connection cable of the switch- ing system must only be connected a Mains connection cable by a suitably qualified and compet- b Connection to window contact...
  • Page 64 Installation  Loosen the lug and pull the plug out. Connecting the e-box  Connect the operating voltage and fan control cables to the e-box and the fan.  Connect the control unit cable to the e-box. The socket positions are designed in such a way that they cannot be mixed ...
  • Page 65: Ducting

    Installation Ducting  If the downdraft extractor is used at the same time as a heating appli- ance that relies on oxygen from the same room, there is a risk of toxic fumes. It is essential that the “Warning and ...
  • Page 66: Electrical Connection

    30 mA. gerous. Miele cannot be held liable for unauthorised work. Miele cannot be held liable for dam- age or injury caused by the lack of or inadequacy of an on-site earthing system (e.g. electric shock).
  • Page 67 A suitable connec- lowing depending on installation: tion cable is available to order from Safety fuses Miele.  Completely remove fuses. Automatic circuit breakers  Press the (red) test button until the middle (black) button springs out.
  • Page 68: Product Data Sheets

    The following data sheets apply to the models described in this operating instruc- tion manual. Data sheet for household cooker hoods In acc. with delegated regulation (EU) No. 65/2014 and regulation (EU) No. 66/2014 MIELE Model name / identifier CSDA 7000 Annual Energy Consumption (AEC 29,3 kWh/year...
  • Page 71 Tel: +65 6735 1191 Fax. +971 4 3418 852 Fax: 011-46 900 001 Fax: +65 6735 1161 800-MIELE (64353) E-mail: customercare@miele.in E-Mail: info@miele.com.sg E-Mail: info@miele.ae Internet: www.miele.in Internet: www.miele.sg Website: www.miele.ae Manufacturer: Miele & Cie. KG, Carl-Miele-Straße 29, 33332 Gütersloh, Germany...
  • Page 72 CSDA 7000 FL en-GB M.-Nr. 10 746 530 / 05...

Table of Contents