Maintenance Of The External Fan; Bearings - Siemens 1PL618 Series Operating Instructions Manual

Ac compact drives;
Table of Contents

Advertisement

Table 7-1
Measures
Initial inspection
Continuous lubrication
(Machines without regreasing
device )
Machines with regreasing
device (option)
Clean
General inspection
[ID: 356]
7.1.3

Maintenance of the external fan

Procedure
● Check the external fan VDI 2056 annually for mechanical vibrations. The maximum
● Regularly clean and inspect the fan. Impeller and frame are subject to natural wear
● Refer to the maintenance and service information provided by the manufacturer of the
7.1.4

Bearings

Description
The three-phase motors have grease-lubricated, rolling-contact bearings. A regreasing
device is optional.
A deep-groove ball bearing is installed at the NDE as a locating bearing. Depending on the
type of load, a deep-groove ball bearing or cylindrical-roller bearing is installed at the DE as
a floating bearing.
A5E00215731A AD
Siemens AG Operating Instructions 2.02 1PL618
Operating period intervals
permissible vibrational severity is 2.8 mm/s measured on the end shield of the impeller-
side motor bearing.
depending on the area of application and displacement medium.
WARNING
Impeller can crack
Due to deposits and the resulting imbalance there is a hazard of fatigue fracture of the
impeller. The impeller can crack in operation. Death, serious injury, or material damage
can result.
Regularly clean and inspect the fan.
external fan.
Operating period intervals
After 500 operating hours
Belt operation 12 000 h
Coupling operation 20 000 h
(see lubrication instruction plate)
depending on local degree of
pollution
Approximately every 16000
operating hours
Maintenance
7.1 Maintenance
Intervals
after 6 months at the latest
After 2 years at the latest
51

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

1pl61841pl6186

Table of Contents