Chapter 5, ST40 Compass Instrument
Chapter 5:

Input/output signals

Self-test procedure

ST40 Instruments Service Manual 83149-2
ST40 Compass Instrument
STALK (Yellow)
BATT- (Screen)
BATT+ (Red)
Connections to instrument
Signal
Description
STALK
Intermittent streams of (nominal) 12 V pulses
BATT-
0 V
BATT+
Nominal 12 V dc supply
VREF
Fluxgate 2.5 V
FGB
Sense B
SCREEN
Fluxgate 0 V return
FGA
Sense A
FGDRIVE
Fluxgate drive
Refer also to the ST40 Compass circuit diagram.
Each ST40 instrument has built-in self-test functions to aid fault diagnosis.
To self-test an ST40 Compass instrument:
• Press the
and
keys simultaneously for 4 seconds, to access self-test mode,
then within 2 seconds, press the
self-test stage 1.

Self test stage 1

When entering self test stage 1, the instrument beeps and the display shows TEST 1,
for 1 second. The following tests are then performed automatically:
Raymarine
Limited
SCREEN (White)
FGDRIVE (Blue)
and
keys together momentarily, to start
VREF (Red)
FGB (Green)
FGA (Yellow)
D4837-2