Page 1
ERO28C*C ERO28RAC*C Installation/Care/Use Manual ™ ® Soft Sides Refrigerated Fountains with FLEXI-GUARD SEE FIG. 7 ERO28C ERO28RAC Installer To assure you install this model easily and correctly, PLEASE READ THESE SIMPLE INSTRUCTIONS BEFORE STARTING THE INSTALLATION. CHECK YOUR INSTALLATION FOR COMPLIANCE WITH PLUMBING, ELECTRICAL AND OTHER APPLICABLE CODES.
ERO28C*C ERO28RAC*C INSTALLATION INSTRUCTIONS 1. Install mounting frame. See mounting frame instructions. 2. Install remote chiller. Remove front panel of chiller. Slide chiller onto the shelf and position it to the left within the guides on the shelf. 3. Attach solenoid valve assy to the underside of cross member of mounting frame on electric eye unit. See Figure 9.
Page 4
ERO28C*C ERO28RAC*C PARTS LIST TROUBLE SHOOTING AND MAINTENANCE ITEM NO. PART NO. DESCRIPTION 1. Orifice Assy: Minerals deposits on orifice can cause water flow to spurt or not regulate. Mineral deposits may be removed from the orifice with a small round...