Bristan AR2 SHXVOFF C (D2) Installation Instructions & User Manual

Bristan AR2 SHXVOFF C (D2) Installation Instructions & User Manual

Advertisement

Quick Links

Specifications
Cold Water Supply
Working Pressures
Min: 0.2 bar
Max: 5.0 bar
3.0
3.0
2.0
2.0
1.0
4.0
1.0
4.0
0.2
5.0
0.2
5.0
Pressure
Pressure
BAR
BAR
Min: 5°C Max: 25°C
Maximum Static Pressure: 10.0 bar
HP-S High Pressure - Shower
TMV DESIGNATION
LP-S Low Pressure - Shower
Tools You'll need
Pencil
Flat head
Drill
Screwdriver
Prior to Installation
All products manufactured and supplied by Bristan are safe to use provided that
they are installed, operated and receive regular maintenance in
accordance with these instructions.
This product needs to be installed in accordance with, and meet the
requirements of the Water Supply (Water Fittings) Regulations 1999 and
current by-laws. For full Installation Requirements & Notes (IRN) please
visit wras.co.uk/directory.
Isolation valves must be fitted to the inlet water supplies to ensure ease of future
maintenance.
Before installing this product the water supply must be thoroughly flushed in
order to remove any swarf, solder etc.
This product must not be modified in any way as this will invalidate the
guarantee.
Full access must be made available for future maintenance/servicing purposes.
Before drilling into walls, check that there are no hidden electrical wires,
cables or water supply pipes. This can be checked with the aid of an
electronic detector.
If power tools are used do not forget to:
- Wear eye protection
- Unplug equipment after use
If in doubt, contact a registered plumber or your Local Water Authority or
the Secretary of the Institute of Plumbing, address as follows:-
The Institute of Plumbing,
64 Station Lane,
Hornchurch,
Essex,
RM12 6NB, Tel: 01708 472791
Installation Instructions
& User Guide
Please leave these instructions
with the end user
Product Code: AR2 SHXVOFF C (D2)
Inlet Water Temperature
Inlet Dimensions
Hot Water Supply
65°C
25°C
60°C
5°C
60-65°C Recommended
Factory pre-set
The inlet hot water must be at
least 10°C above the required
42°C
Cross head
Spanner
Pipe Cutter
Hexagonal Keys Socket Spanner
Screwdriver
Pack Contents
x2
x2
x2
Installation
1
Identify the required positition of the
valve and prepare the water supply pipes.
Supply pipes should be 150mm apart.
150mm
Using the backplate supplied with the
Centres
wallmount, mark and drill holes.
2
Inlet Connections
15mm
Compression
IMPORTANT
blend temperature.
Secure the rubber backplate
and backplate into place.
4
Push shrouds to the
back of the wall outlet,
securing them against
the rubber fixing plate
Isolation
1
x1
Remove the concealing
cap from the shroud.
3
Secure the isolator
onto the backplate
ensuring the olive is
positioned over the
pipework correctly.
5
Secure the shower to
the wall mount.
2
Rotate the shroud until
the opening aligns with
the isolation screw.
Turn the screw to isolate
the water. Reverse the
process when turning
the water back on.

Advertisement

loading

Summary of Contents for Bristan AR2 SHXVOFF C (D2)

  • Page 1 Screwdriver Pack Contents Prior to Installation All products manufactured and supplied by Bristan are safe to use provided that they are installed, operated and receive regular maintenance in accordance with these instructions. This product needs to be installed in accordance with, and meet the requirements of the Water Supply (Water Fittings) Regulations 1999 and current by-laws.