Content
1
About this document
1.1 Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.2 Target group: authorised qualiied personnel. . . . . . . . . . . . . . . . . .1
1.3 Explanation of the symbols used . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.4 Appropriate use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.5 General safety instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.6 Warning about misuse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.7 Exclusion of liability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
2
2.1 Ordering code . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2.2 Special versions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2.3 Destination and use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2.4 Technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2.5 Safety classiication . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
3
3.1 General mounting instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
3.2 Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
4
4.1 General information for electrical connection. . . . . . . . . . . . . . . . . .3
5
5.1 Mode of operation of the safety outputs. . . . . . . . . . . . . . . . . . . . . .3
5.2 Magnet control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
5.3 Programming the slave address . . . . . . . . . . . . . . . . . . . . . . . . . . .4
5.4 Coniguration of the safety monitor . . . . . . . . . . . . . . . . . . . . . . . . .4
5.6 Read-out of the parameter port . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
6
6.1 Functional testing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
6.2 Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
7
7.1 Disassembly. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
7.2 Disposal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
8
8.1 EC Declaration of conformity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
Encontrará el manual de
ES
instrucciones actual en su
idioma oicial de la UE en nu-
estra página de Internet www.
schmersal.net.
Il manuale d'istruzioni aggior-
IT
nato nella vostra lingua (lingua
uficiale UE) è scaricabile in
Internet all'indirizzo www.
schmersal.net.
1 About this document
1.1 Function
This operating instructions manual provides all the information you
need for mounting, set-up and commissioning for the safe operation
and disassembly of the safety switchgear. The operating instructions
must be available in a legible condition and a complete version within
the vicinity of the device.
1.2 Target group: authorised qualiied personnel
All operations described in this operating instructions manual must
be carried out by trained specialist personnel, authorised by the plant
operator only.
Please make sure that you have read and understood these operating
instructions and that you know all applicable legislations regarding
occupational safety and accident prevention prior to installation and
putting the component into operation.
The machine builder must carefully select the harmonised standards to
be complied with as well as other technical speciications for the selec-
tion, mounting and integration of the components.
1.3 Explanation of the symbols used
Information, hint, note:
This symbol is used for identifying useful additional informa-
tion.
Caution: Failure to comply with this warning notice could
lead to failures or malfunctions.
Warning: Failure to comply with this warning notice could
lead to physical injury and/or damage to the machine.
1.4 Appropriate use
The products described in these operating instructions are developed to
execute safety-related functions as part of an entire plant or machine. It
is the responsibility of the manufacturer of a machine or plant to ensure
the proper functionality of the entire machinery or plant.
The safety switchgear must be exclusively used in accordance with the
versions listed below or for the applications authorised by the manufac-
turer. Detailed information regarding the range of applications can be
found in the chapter "Product description".
1.5 General safety instructions
The user must observe the safety instructions in this operating instruc-
tions manual, the country-speciic installation standards as well as all
prevailing safety regulations and accident prevention rules.
Further technical information can be found in the Schmersal
catalogues or in the online catalogue on the Internet: www.
schmersal.net.
The information contained in this operating instructions manual is provi-
ded without liability. Subject to technical modiications.
There are no residual risks, provided that the safety instructions as well
as the instructions regarding mounting, commissioning, operation and
maintenance are observed.
1.6 Warning about misuse
In case of inadequate or improper use or manipulations of the
safety switchgear, personal hazards or damage to machinery
or plant components cannot be excluded. The relevant requi-
rements of the standard EN 1088 must be observed.
1.7 Exclusion of liability
We shall accept no liability for damages and malfunctions resulting from
EN
AZM 170 AS
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AZM 170 AS Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for schmersal AZM 170 AS Series

  • Page 1: Table Of Contents

    4.1 General information for electrical connection....3 Further technical information can be found in the Schmersal catalogues or in the online catalogue on the Internet: www.
  • Page 2: Product Description

    Operating instructions Solenoid interlock AZM 170 AS defective mounting or failure to comply with this operating instructions LED indication manual. The manufacturer shall accept no liability for damages resul- The LED's have the following meaning: ting from the use of unauthorised spare parts or accessories. Green LED AS-Interface supply voltage For safety reasons, invasive work on the device as well as arbitrary re-...
  • Page 3: Safety Classiication

    Operating instructions Solenoid interlock AZM 170 AS Diagnostic information: Green LED: AS-Interface supply voltage Red LED: AS-Interface communication error or slave address = 0 3.2 Dimensions Yellow LED: Enabling status All measurements in mm. Input module address: preset to address 0, can be changed through AS-interface bus master or hand-held programming device Auxiliary voltage magnet:...
  • Page 4: Magnet Control

    Operating instructions Solenoid interlock AZM 170 AS 5.2 Magnet control The coniguration of the safety monitor must be tested and The control system with the AS-Interface Master can lock and unlock the conirmed by a qualiied and authorised safety expert/safety engineer.
  • Page 5: Set-Up And Maintenance

    Operating instructions Solenoid interlock AZM 170 AS AZM 170 B ST-AS .A. B-variant, power to lock (magnet-operated locking) System condition Magnet input AS-i power Authorized operation SaW code Parameter port AS-i D Out: 0 Green LED Yellow LED Authorized operation P0 - P1 - P2 - P3 Safety guard open Safety guard closed...
  • Page 6: Appendix

    Heinz Schmersal Managing Director Note The currently valid declaration of conformity can be downloa- ded from the internet at www.schmersal.net. K. A. Schmersal GmbH Industrielle Sicherheitsschaltsysteme Möddinghofe 30, D - 42279 Wuppertal Postfach 24 02 63, D - 42232 Wuppertal...