Download Print this page

Set Up Information / Batteries - Health O Meter 2595KL User Instructions

Digital chair scale
Hide thumbs Also See for 2595KL:

Advertisement

Available languages

Available languages

SET UP / BATTERIES
1.
Place batteries in the battery holder (see "Replacing Batteries" below) and then plug the
scale's power adapter into the chair scale assembly and into the power source.
2.
Press the ON/OFF button to turn the scale on. The display will show "start", then "0.0".
3.
When the self-test function is complete:
The digital display should read
"LB" should be indicated on the right side of the display. (To change the default
units of the scale to kilograms (kg), please contact Health o meter® Professional
Technical Support at 1.800.638.3722 or 1.708.598.9100).
4.
Place a weight [not to exceed 600 Lb (270 kg)] on the scale. The digital display should
------
blink "
" until the weight calculation is complete.
------
5.
Press the LB/KG button to select the weight mode, either in kilograms or pounds.
6.
Press the REWEIGH button; the digital display should again read the weight of the item
on the scale. Pressing the REWEIGH button will reweigh the patient without removing
them from the scale.
7.
Remove the weight from the scale. The digital display should continue to show the
weight of the item that was on the scale.
8.
Press the ZERO button; the digital display will return to zero.
9.
Press the ON/OFF button to turn the scale off. The display will show "OFF" and then turn
the scale off.
10.
Disconnect the power source adapter from the scale, and then switch on the scale using
the ON/OFF button. The scale should automatically change over to battery power.
NOTE: If the set up procedure failed, go to the troubleshooting instructions. If the problem is
still not corrected, refer to qualified service personnel.
Replacing Batteries
1.
Disconnect the scale from the adapter power source.
2.
Loosen two knobs found underneath the display until the battery holder is released from the chair scale
assembly and rests on the knobs. Carefully pull out the cable to provide access to the connector.
Disconnect the battery holder cable connector from the chair scale cable connector by pushing the button.
3.
Raise the battery holder and simultaneously rotate it counterclockwise 1/4 turn. Carefully remove the
holder from the chair scale assembly.
4.
Replace the batteries with new ones.
5.
Place the battery holder on the plastic knobs by rotating it 1/4 turn clockwise.
6.
Plug the battery holder cable connector to the chair scale cable connector.
7.
Hold the battery holder close to the chair scale assembly and tighten the two plastic knobs to secure in
place. Be careful not to damage the cable.
"0.0".
Figure 2. Replacing Batteries
4

Hide quick links:

Advertisement

loading