Pretika SonicLift ST261 Instructions For Use Manual

Facial toning

Advertisement

Quick Links

1

Advertisement

Table of Contents
loading

Summary of Contents for Pretika SonicLift ST261

  • Page 2 Congratulations and thank you for being a Pretika customer! Before you start, please take a moment to get to know your SonicLift® and how it works. SonicLift® delivers low level, gentle electrical micro-current that continually alternates between the positive and negatives spheres – with settings that control the current output from 0 to 400 microamps.
  • Page 3: Table Of Contents

    Contents 1.0 Recommendation of Use ............ 4 1.1 Contraindications ............4 1.2 Warnings ..............5 1.3 Precautions ..............7 1.4 Adverse Reactions ............8 1.5 Travel Tips ..............8 2.0 Intended Use & Indications for Use ........8 3.0 Device Description .............. 8 3.1 Accessories List ............
  • Page 4: Recommendation Of Use

    1.0 RECOMMENDATION OF USE Please read the complete instruction manual before you use the SonicLift (Model: ST261). It will give you a better understanding of how the product works, and you’ll be able to enjoy the best results. 1.1 Contraindications Never use this device over any suspicious or cancerous lesion.
  • Page 5: Warnings

    10) Never operate this device if it has been damaged. If it is not working properly, if it has been dropped or damaged, or submerged in water. Return the device to Pretika Corporation for examination and repair. 11) Do not disassemble the device as this may cause damage, malfunction or personal injury.
  • Page 6 16) The use of ACCESSORIES, transducers and cables other than those specified, with the exception of transducers and cables sold by the MANUFACTURER of the ME EQUIPMENT or ME SYSTEM as replacement parts for internal components, may result in increased EMISSIONS or decreased IMMUNITY of the ME EQUIPMENT or ME SYSTEM.
  • Page 7: Precautions

    1.3 Precautions 1) Stop immediately if you experience any adverse effect of have a concern regarding use. Contact your skin care professional, doctor or healthcare provider. 2) Use this device only for its intended use as described in this Instructions for Use Manual.
  • Page 8: Adverse Reactions

    1.4 Adverse Reactions Some patients may experience skin irritation of hypersensitivity due to the electrical stimulation or electrical conductive medium. The irritation can usually be reduced by using an alternate conductive medium. 1.5 Travel Tips The device’s lightweight, compact design makes it an easy travel companion. There are some travel tips for you: If traveling outside the U.S., use country specific charging adaptors.
  • Page 9: Accessories List

    only be used for the purpose stated – namely for the stimulation of facial muscles as indicated in the instruction manual for personal beauty purposes. All other uses shall be deemed improper. 3.1 Accessories List Name Quantity Picture Main Device Charger Station Charging Adaptor...
  • Page 10: Main Device

    3.2 Main Device 3.2.1 Buttons Spheres ON/OFF Button Mode Button Intensity Button • On/Off Button An On/Off button on the main device of the SonicLift can turn on or turn off it. When power is on, the orange Power light will be on; when power is off, all the light indicators will be off.
  • Page 11: Working Modes

    3.2.2 Working Modes Program Name Display Description Vibration Motor Vibration Mode Micro- Current Output Current Mode 3.2.3 Intensity The intensity level has 4 steps per channel. With every push of the INTENSITY But- ton you increase / decrease the intensity by one step. Indicator lights Mode 1 Mode 2...
  • Page 12: Using Instructions

    Ensure the entire area being treated is saturated with the Conductive Gel. On your clean, dry face apply Pretika Conductive Gel by tapping into your skin with your fingertips. We recommend applying the Gel to each treatment area or half the face at a time, so that the Gel does not dry out.
  • Page 13: Adjust Intensity

    4.4 Adjust Intensity Adjust the intensity level for each working mode using the INTENSITY Button on the inside handle of your device repeatedly. Press the INTENSITY Button, the inten- sity will increase from Level 1 to Level 4; press it one more time, the intensity will be back to Level 1.
  • Page 14: After Treatment

    A full charge is indicated by the BATTERY Light turning green. Note: - Pretika recommends to unplug the Charging Adaptor after each full charge and conveniently store the Adaptor until charging is required. - You can leave the SonicLift (Model ST261) in the Cradle as a counter top stand when not charging.
  • Page 15: Maintenance

    5.0 MAINTENANCE The following maintenance instructions are important to ensure that your device continues to work as it was designed. Failure to follow these instructions may cause your device to stop delivering the required dose or to stop working altogether. 5.1 Cleaning Simply follow these easy instructions: - Lightly dampen a washcloth with water.
  • Page 16: Disposal Of Electrical

    6.0 SERVICE The SonicLift (Model ST261) has no parts you can fix. Do not try to repair it. If the SonicLift requires service, please contact the selling retailer or Pretika Corporation. All returned units to the manufacturer for repair, including Warranty...
  • Page 17: Outside Warranty Period

    Be sure to include a check or money order payable to Pretika Corporation in the amount of $40.00 to cover handling and postage charges. Then we will send a replacement unit.
  • Page 18: Product Information

    8.0 PRODUCT INFORMATION 8.1 Specification Basic Unit Characteristics Power Source 3.7V li-battery - Method of Line Current Isolation Type BF Applied Part Comply with IEC 60601-1 - Patient leakage current and IEC 60601-2-10 - Normal Condition - Single Fault Condition Average DC current through electrodes when device is on but no pulses are being applied...
  • Page 19 8.1 Specification Continue Basic Unit Characteristics Indicates on/off status, low battery, LED Indicator of mode information, intensity level information. Time Range (minutes) Compliance with Voluntary Standards Comply with IEC 60601-1 and IEC 60601-2-10, IEC 60601-1-2 Compliance* with 21 CFR 898 Main Unit Weight 248g Charge station: 200g;...
  • Page 20 8.1 Specification Continue Output Specification Waveform and Shape Pulsed, symmetric biphasic, rectangular 0.14V@500Ω 0.5V@2KΩ Maximum Output Voltage (+/- 10%) 0.2V@10KΩ 0.24mA@500Ω 0.25mA@2KΩ Maximum Output Current (+/- 10%) 0.02mA@10KΩ Net Charge (per pulse) 0.339mC @500Ω Maximum Phase Charge @500Ω Maximum Average Current 0.198mA @500Ω...
  • Page 21: Mode Specification Table

    8.1 Specification Continue Additional Features Temperature: 5 ~ 45° Environment for operation Humidity: 20 ~ 65% RH Temperature: 0 ~ 45° Environment for storage Humidity: 10 ~ 90% RH 8.2 Mode Specification Table Vibration Output Specification (Contraction and Relaxation Time) Level 1 Level 2...
  • Page 22 8.2 Mode Specification Table Continue Vibration Output Specification (Contraction and Relaxation Time) Level 3 Level 4...
  • Page 23 8.2 Mode Specification Table Continue Current Stimulation Output Specification Basic Waveform Level 1 T: 0 Vpp: 0Vdc Cycle Waveform Basic Waveform Level 2 Cycle Waveform Basic Waveform Level 3 Cycle Waveform...
  • Page 24 8.2 Mode Specification Table Continue Current Stimulation Output Specification Basic Waveform Level 4 Cycle Waveform...
  • Page 25: Label & Symbols

    8.3 Label & Symbols...
  • Page 26 8.3 Label & Symbols Symbols Description CONSULT INSTRUCTIONS FOR USE. Symbol for “ATTENTION, CONSULT ACCOMPANYING DOCUMENTS”. BATCH CODE. This symbol should be accompanied by batch code. Symbol for “SERIAL NUMBER”. This symbol shall be accompanied by the manufacturer’s serial number. DATE OF MANUFACTURE.
  • Page 27: Manufacturer Information

    9 MANUFACTURER INFORMATION Company: Pretika Corporation Address: 12215 Holly Street Riverside, CA 92509 Tel: 9491882-8818 Fax: 949-481-8828 Email: customerservice@pretika.com...
  • Page 28 Facial Toning Lift, Firm and Tone Skin...

Table of Contents