IBM Bull Escala E5-700 Manual page 96

Table of Contents

Advertisement

Environmental Limits:
v Operating
– Temperature: 0 to 40 C (ambient air temperature)
– Humidity: 5% to 95% (non-condensing)
– Wet Bulb: 29 C
– Altitude: 0 - 7000 ft
v Storage
Temperature: 1 to 60 C
– Humidity: 5% to 80% (non-condensing)
Wet Bulb: 29 C
v Shipping
Temperature: -40 to 60 C
Humidity: 5% to 100% (non-condensing)
Wet Bulb: 29 C
Power Consumption
Table 34. 7036-P16 power consumption
Voltage (input)
100/250VAC nominal
90/264VAC maximum
47/63 Hz
Throughput considerations
The limits on throughput are a function of the network and the server or server partition to which the
7036-P16 ports are configured.
System port throughput:
The 7036-P16 supports full-duplex operation up to 230K bps on all ports. Operation with all sixteen ports
running full-duplex at 230K bps is supported.
Network throughput:
The 7036-P16 is an Ethernet attached device and as such, any number may be attached to a given
network. However, attaching more devices to any network reduces the overall network throughput and
care must be taken to not overload any given network.
Testing has shown that as many as eight 7036-P16 devices may be attached to a network without
adversely affecting network throughput. Eight 7036-P16 devices will support up to 128 asynchronous
EIA-232 connections. More devices may be attached, but network performance may be adversely affected.
Server or partition throughput:
Each 7036-P16 provides 16-Ports of asynchronous EIA-232 connectivity over a 10/100 Ethernet port at
speeds up to 230K bps. Given that any number of 7036-P16s may be attached to a server or partition, a
single server or partition could in effect have a very large number of asynchronous EIA-232 connections
that could adversely affect any single server or partition.
84
Power Systems: Managing devices
Current (amp)
0.8 A Maximum
40A in rush
2A fuse
Watt
12 W typical