Summary of Contents for ADB Safegate RELIANCE AGLAS-C

  • Page 1 RELIANCE Intelligent Lighting Remote Control Device (AGLAS-C) Remotes User Manual 96A0481, Rev. B, 2019/10/01...
  • Page 3 Where applicable, per FAA EB67 (applicable edition), ADB SAFEGATE L858(L) Airfield Guidance Signs are warranted against electrical defects in design or manufacture of the LED or LED specific circuitry for a period of 4 years. ADB SAFEGATE LED light fixtures (with the exception of obstruction lighting) are warranted against mechanical and physical defects in design or manufacture for a period of 12 months from date of installation;...
  • Page 4 This manual could contain technical inaccuracies or typographical errors. ADB SAFEGATE BVBA reserves the right to revise this manual from time to time in the contents thereof without obligation of ADB SAFEGATE BVBA to notify any person of such revision or change. Details and values given in this manual are average values and have been compiled with care. They are not binding, however, and ADB SAFEGATE BVBA disclaims any liability for damages or detriments suffered as a result of reliance on the information given herein or the use of products, processes or equipment to which this manual refers.
  • Page 5: Table Of Contents

    4.5.1 A sample spreadsheet would contain:..............................25 5.0 Parts......................................27 5.1 Spare Components........................................27 A.0 SUPPORT....................................29 A.1 ADB SAFEGATE website......................................29 A.2 Recycling............................................30 A.2.1 Local authority recycling...................................30 A.2.2 ADB SAFEGATE recycling..................................30 96A0481, Rev. B, 2019/10/01 Copyright ADB Safegate, All Rights Reserved ©...
  • Page 6 RELIANCE-C Remote Control Device TABLE OF CONTENTS Copyright ADB Safegate, All Rights Reserved ©...
  • Page 7: Safety

    1.0 Safety Introduction to Safety This section contains general safety instructions for installing and using ADB SAFEGATE equipment. Some safety instructions may not apply to the equipment in this manual. Task- and equipment-specific warnings are included in other sections of this manual where appropriate.
  • Page 8: Introduction To Safety

    Using this equipment in ways other than described in this manual may result in personal injury, death or property and equipment damage. Use this equipment only as described in this manual. Failure to follow this instruction can result in serious injury or equipment damage Copyright ADB Safegate, All Rights Reserved ©...
  • Page 9: Material Handling Precautions: Storage

    • Allow only qualified personnel to perform maintenance, troubleshooting, and repair tasks. • Only persons who are properly trained and familiar with ADB SAFEGATE equipment are permitted to service this equipment. • An open airfield current circuit is capable of generating >5000 Vac and may appear OFF to a meter.
  • Page 10 RELIANCE-C Remote Control Device Safety Copyright ADB Safegate, All Rights Reserved ©...
  • Page 11: Reliance Remote

    Airfield Lighting Vault (ALV). They produce a constant current output to the airfield series circuit that light the airfield lighting fixtures. ADB SAFEGATE’s trademarked abbreviation for Airfield Ground Lighting Automation System which is a term that describes the Reliance Remore, Master, PC ™...
  • Page 12: Aglas Remote Introduction

    Developed in accordance with IEC 61508 Introduction The RELIANCE Intelligent Lighting (IL) is ADB SAFEGATE's state-of-the art individual lamp control and monitoring system. ® RELIANCE Intelligent Lighting provides a radical leap in performance over prior airfield power line carrier systems. The system is designed to communicate on the existing airfield series circuit power line without requiring separate dedicated cabling.
  • Page 13 • Can be used as a stand-alone monitoring system or integrated with an ALCS (Airfield Lighting Control System). 96A0481, Rev. B, 2019/10/01 Copyright ADB Safegate, All Rights Reserved ©...
  • Page 14 (dual) Maximum circuit load (CCR power) 30 kVA Power consumption Max. 8 W at 6.6 A Max. 15 W for power supply 115-230 V Max. 65 W on primary circuit at 6.6 A Copyright ADB Safegate, All Rights Reserved ©...
  • Page 15 Insulation resistance of the series circuit against the L-824 shield or ground 50 Megaohms minimum Secondary transformer attenuation ≤ 23 dB at 100 kHz Notes Contact ADB Safegate for support Technical requirement, not excluding ICAO /FAA compliance 96A0481, Rev. B, 2019/10/01 Copyright ADB Safegate, All Rights Reserved...
  • Page 16: General

    RELIANCE Remote is available in the following four versions: • RELIANCE Remote single channel for controlling one light (airfield ground lighting) • RELIANCE Remote dual channel for controlling two lights (airfield ground lighting) Copyright ADB Safegate, All Rights Reserved ©...
  • Page 17: Illustration

    2 weeks. After this period, complaints about the delivery will not be accepted. In the event of the goods being returned, the same transport packaging must be used. See Figure The number on the nameplate must be checked against the order number on the delivery note. 96A0481, Rev. B, 2019/10/01 Copyright ADB Safegate, All Rights Reserved ©...
  • Page 18: View Of The Device With Connections

    3. Cable with 2-pin socket (in compliance with FAA L-823) for connection to the light on channel B (for dual Remote only) (X4) 4. Ground cable connection (X2) 5. RELIANCE Remote housing 6. RELIANCE Remote Label for Remote ID number. Note See nameplate of RELIANCE Remote (Figure 2) for identification of connections marked “X”. Copyright ADB Safegate, All Rights Reserved ©...
  • Page 19: View Of The Device With Connections

    Figure 4: View of the RELIANCE Utility Remote Cabinet Note See the remote cabinet wiring diagram for connections. 2.2.6.1 Construction The AGLAS Remote is sealed to make it watertight and gas-tight and must not be opened. 96A0481, Rev. B, 2019/10/01 Copyright ADB Safegate, All Rights Reserved ©...
  • Page 20: Theory Of Operation

    Constant Current Regulator (CCR) powering the airfield lighting circuit and many slave units, or Remotes, collocated with individual lights in the field. A typical RELIANCE topology is provided in Figure Figure 6: Typical RELIANCE Topology Copyright ADB Safegate, All Rights Reserved ©...
  • Page 21 Masters also communicate amongst themselves to maintain communication timing synchronization. Each master communicates with the fixtures on its respective circuit. Figure 7: Series Circuit Master / Fixture Architecture 96A0481, Rev. B, 2019/10/01 Copyright ADB Safegate, All Rights Reserved ©...
  • Page 22 RELIANCE-C Remote Control Device RELIANCE Remote Copyright ADB Safegate, All Rights Reserved ©...
  • Page 23: Installation

    Because the communication signal is coupled magnetically, the distance between the transformers should also not be less than 2-inch (50mm). Minimum distance between remote cable feed-through and pit walls is 2-inch (50 mm). Figure 9: Remote max. bending radius 96A0481, Rev. B, 2019/10/01 Copyright ADB Safegate, All Rights Reserved ©...
  • Page 24: Connection To The Series Transformer And The Light Fitting(S)

    1. Place the heat shrink sleeve over the light inset plug wire. 2. Connect the inset light plug to the Remote receptacle designated CHANNEL A (and CHANNEL B if used). 3. Pull the heat shrink sleeve over the plug-to-receptacle connection. Heats shrink the sleeve. Copyright ADB Safegate, All Rights Reserved ©...
  • Page 25 Repeat steps 1 through 3 for the Remote plug designated TRANSFORMER and the transformer secondary receptacle. 96A0481, Rev. B, 2019/10/01 Copyright ADB Safegate, All Rights Reserved ©...
  • Page 26: Utility Remote Enclosure Wiring Diagram

    RELIANCE-C Remote Control Device Installation 3.3 Utility Remote Enclosure Wiring Diagram Copyright ADB Safegate, All Rights Reserved ©...
  • Page 27: Earth Grounding

    5. Removing a RELIANCE Remote: first, separate the series circuit connections X3 and X1 and, in the case of the dual RELIANCE Remote, X4 at the cable plug connections. Then, open the ground connection X2 by unscrewing the earth ground screw. 96A0481, Rev. B, 2019/10/01 Copyright ADB Safegate, All Rights Reserved ©...
  • Page 28 7. Switch on the associated series circuit and verify if the replaced remote connected lamp(s) are functioning (for RGL remotes: blinking). 8. Follow the “change remote” procedure as described in “96A0430 RELIANCE Configuration Software - User Manual” to make the replaced remote operational. Copyright ADB Safegate, All Rights Reserved ©...
  • Page 29: Modes Of Operation Of An Reliance Remote

    “Blink” (light flashing; no information as to whether the light is “On” or “Off” at the time of polling). On the Graphical User Interface (GUI), the status of each light is indicated by the terms given in quotation marks. 96A0481, Rev. B, 2019/10/01 Copyright ADB Safegate, All Rights Reserved ©...
  • Page 30: Switch Status Under Special Circumstances

    Delayed switch-on/off setting 2 (20ms delay per lamp) • Delayed switch-on/off setting 3 (30ms delay per lamp) • Delayed switch-on/off setting 4 (40ms delay per lamp) • Delayed switch-on/off setting 5 (50ms delay per lamp) Copyright ADB Safegate, All Rights Reserved ©...
  • Page 31: Spreadsheet

    If the remote is a Dual type: reference must be filled in for Channel B also, even if the light fixture is the same as for Channel A (one fixture with 2 lamps). Underlined information is mandatory and the absolute minimum required data. 96A0481, Rev. B, 2019/10/01 Copyright ADB Safegate, All Rights Reserved ©...
  • Page 32 RELIANCE-C Remote Control Device Modes of Operation of an RELIANCE Remote Copyright ADB Safegate, All Rights Reserved ©...
  • Page 33: Parts

    44A7352-10 GB Industrial Grade Flash Card 105A1155 92 CFM RELIANCE Master Fan Assembly 44A7657 RELIANCE Master Touchscreen 105A1108 Low-voltage PCB Assembly 44A7605 High-voltage PCB Assembly 44A7379-1 Control Module 44A7512 96A0481, Rev. B, 2019/10/01 Copyright ADB Safegate, All Rights Reserved ©...
  • Page 34 RELIANCE-C Remote Control Device Parts Copyright ADB Safegate, All Rights Reserved ©...
  • Page 35: Support

    Table 5: ADB SAFEGATE Support Live Technical Support - Americas If at any time you have a question or concern about your product, just contact ADB SAFEGATE’s technical service department. Trained in all areas of system issues, troubleshooting, quality control and technical assistance, our highly experienced Technical support specialists are available 24 hours a day, seven days a week to provide assistance over the phone.
  • Page 36: Recycling

    A.2.1 Local authority recycling The disposal of ADB SAFEGATE products is to be made at an applicable collection point for the recycling of electrical and electronic equipment. The correct disposal of equipment prevents any potential negative consequences for the environment and human health, which could otherwise be caused by inappropriate waste handling.