1 Explanation of symbols

See chapter 2. Safety
i
Important information for the user
Product can be sterilized in a steam sterilizer (Autoclave)
Can be used in thermal disinfectors
CE-mark – Confirms that this product fulfills all requirements for medical products
REF
Reference number
SN
Serial number

2 Safety

2.1 Description of danger levels
CAUTION
CAUTION is used if a deficiency in adequate care may result in an endangering of the patient, the user or others.
CAUTION
WARNING
WARNING is used if improper use may result in serious injuries.
WARNING
2.2 Safety notes
WARNING
Risk of injury for the patient and the operator
Concerning damages like irregular running noise, irregular vibrations, an unspecific rise in temperature and/or other defects.
WARNING
→ Stop operating immediately and contact our service.
WARNING
Risk of infection
In case of an injury of the tissue in the oral area, do not proceed to work with air-operated instruments because of a high risk of
WARNING
an infection.
Instruction manual
LB41/11P
0123

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the LBH11P and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for mk-dent LBH11P

  • Page 1 Instruction manual LB41/11P 0123 1 Explanation of symbols See chapter 2. Safety Important information for the user Product can be sterilized in a steam sterilizer (Autoclave) Can be used in thermal disinfectors CE-mark – Confirms that this product fulfills all requirements for medical products Reference number Serial number 2 Safety...
  • Page 2 → Before storage, clean, maintain and dry the instrument according to the norm. Store in the original packing, dry and dust- CAUTION proof. We recommend an annual check-up and maintenance of the entire spindle system by MK-dent or by MK-dent authorized personnel. 3 Product description This manual can be used for the following MK-dent products:...
  • Page 3 4 Putting into service and operation WARNING Risk of infection for patients and operator due to non-sterile instruments → Before the first and after each further use the instrument must be processed and sterilized as defined in chapter 5 Processing WARNING according to ISO 17664.
  • Page 4 5.3.2 Mechanical cleaning and disinfection of the interior and the exterior MK-dent recommends thermal disinfectors that fulfill the EN ISO 15883-1 requirements and are approved by the manufacturer for the straight- and contra angle, as well as for high speed handpieces. The cleaning should be carried out at a minimum of 55°C (131°F) and for at least 5 minutes, the disinfection at a minimum of 90°C (194°F) and for at least 5 minutes (for an A0-value >...
  • Page 5 The sterilization was validated with the device Tuttnauer® EHS 3870 in a fractional pre-vacuum process at 134°C (273°F) for 5 minutes. Please note, that the reprocessing procedure performed in your dental office must be validated also. For more information on the entire preparation process download our MK-dent Processing Guide for High- & Low Speed Handpieces from our website www.mk-dent.com/downloadcenter.
  • Page 6 MK-dent is not liable for defects and their consequences that have arisen whose arising may be due to natural wear, improper handling, improper cleaning, or maintenance, non-compliance with operating or manual instructions, calcination or corrosion, contaminated air and water supply or chemical or electrical influences that are unusual or after MK-dent’s instruction for use or other manufacturer‘s instructions are not permitted.

This manual is also suitable for:

Lb41

Table of Contents