Presentation
B1-22
Depending on your vehicle's equipment

Electrical control

Depending on the assembly, the mechanical
control is assisted by an electrical control.
Place lever (1) in the "up" position. Use operat-
ing bar (2).
With the ignition switched on, press button (4).
Since unlocking is automatic, pump until the
cab tilts fully.
To return the cab to the "road" position, place
lever (1) in the "down" position, press button
(4) until the cab locks automatically. Do not
leave your hands on the step during the ma-
noeuvre.
After 2 successive tilting manoeuvres (up and down), wait for 15 minutes for the pump motor
to cool down before starting again.
If you experience difficulty in tilting, return the cab to the "road" position and check the oil
level.
In the event of electrical failure (control or pump), use the mechanical cab tilt control.